Subtask 27-54-45-860-058
B. Aircraft Maintenance Configuration WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE
_______ CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1)
Extend the flaps fully (Ref. TASK 27-50-00-866-008).
(2)
Install the LOCKING TOOL - FLAP/SLAT CONTROL LEVER (98D27803000000) on the flap/slat control lever.
Subtask 27-54-45-865-056
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 6CV B07 121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 8CV Q21
Subtask 27-54-45-010-057
D. Get Access R (1) Put the access platform in the applicable position.
(2)
Put the applicable spoiler in the 'M' (Maintenance) position (Ref. TASK 27-60-00-866-002).
(3)
Put the COLLAR-SAFETY, SPOILER on the piston rod of the servo-control.
(4)
Remove the applicable access panels (Ref. TASK 57-51-37-000-004):
-
FOR 6218CM
remove 575AB, 575BB
-
FOR 6268CM
remove 675AB, 675BB.
4. Procedure
_________
**ON A/C 001-049, 051-061, 101-103, 201-203,
(Ref. Fig. 401/TASK 27-54-45-991-001) R **ON A/C 062-099, 104-149, 151-199, 204-299, 301-399, 401-499,
(Ref. Fig. 401A/TASK 27-54-45-991-001-A)
**ON A/C ALL
(Ref. Fig. 405/TASK 27-54-45-991-004)
CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING
_______
EDGE:
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
-MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Subtask 27-54-45-020-058
A. Removal of the Torque Shaft 6218CM(6268CM)
(1)
Install the LOCK-TORQUE SHAFT (FLAPS AND SLATS) WITH CLAMP-PIVOT (98D27504030001) on a flap torque shaft (Ref. TASK 27-50-00-400-003), outboard of the component to be removed.
(2)
Remove the nuts (74), the bolts (73) and the torque shaft (72).
(3)
Remove the nuts (76), the bolts (77) and the torque shaft (71).
(4)
Remove the universal joint (75).
Torque Shafts- Flap Power Transmission Figure 405/TASK 27-54-45-991-004
1EFF : 1 1R 1CES ALL 1 11 1 27-54-45 Page A410 Aug 01/02
TASK 27-54-45-400-009 Installation of the Torque Shaft 6218CM(6268CM) WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______ NOTICES ARE IN POSITION.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
_______
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
-
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
-MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific safety barriers No specific warning notice No specific access platform 3.5 m (11 ft. 6 in.) No specific Torque Wrench : range 0.20 to 3.60 m.daN
(2.00 to 26.00 lbf.ft)
1EFF : ALL 1 27-54-45Page A411 1 1 Aug 01/02R 1 1 1CES 1
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
Material No. 04-018
GENERAL PURPOSE ASSEMBLY PASTE (Ref. 20-31-00)
Material No. 04-022 USA MIL-PRF-81322 GRADE 2
SYNTHE.HYDROCARBON GREASE HIGH PRESSURE
(Ref. 20-31-00)
Material No. 11-026 GB DEF-STAN 68-148/1
SOLVENT GENERAL PURPOSE (Ref. 20-31-00)
Material No. 15-007 AIB TN 10138 TYPE II GRADE 1 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵5(47)