曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
at 20°C. Battery capacity will drop with decreasing temperature.
Should the battery become weak during operation, the lower line of
the LCD display will indicate “LOW BATT.” An audible beeper will
begin to sound. At this point, there will be 1 hour of operating time
left. When the voltage reaches a level where reliable measurements are
no longer possible, the unit will turn itself off. It is good practice to
leave the instrument on charge at all times if emergency use is
anticipated.
Flow Verification Proper flow should always be verified before using the PortaSens
for leak detection. When the unit is turned on, a pump continuously
delivers an air sample to the flow cell. In normal operation, the flow
rate is approximately 300 cc/min. In order to allow quick verification
of proper flow, a flowmeter is included in the PortaSens kit. Turn the
instrument on and connect the sampling wand. Place the tip of the
sampling wand into the tubing adapter attached to the flowmeter. Hold
the flowmeter in the vertical position and verify that the flow rate is
above 150 cc/min.
Power Down In order to turn the unit off, press and hold the switch for
approximately 3 seconds, until the “POWER DOWN” message appears
on the display and then release.
10/2002-04 Treatment Manual 9-1-1
PPQ
Treatment Manual
9 Glossary 1
Acronyms, Abbreviations, and Terms
a.i. active ingredient
ACGIH American Conference of Governmental Industrial Hygienists
ADI Acceptable Daily Intake
APHIS Animal and Plant Health Inspection Service
BBEP Biotechnology, Biologics, and Environmental Protection
bw body weight
CAS Chemical Abstracts Service
cc cubic centimeters
CERCLA Comprehensive Environmental Response, Compensation, and Liability Act
ChE cholinesterase
CHEMTREC 24-hour emergency telephone service for spills
CNS central nervous system
copra dried coconuts and whole coconuts without the husk
COR Contracting Officer’s Representative
CPK creatine phosphokinase
cu.m cubic meter
CWA Clean Water Act
DHEW U.S. Department of Health, Education, and Welfare
DNA deoxyribonucleic acid
DOT U.S. Department of Transportation
DW drinking water
EPA Environmental Protection Agency
External A pest that normally inhabits the outside or outer part of its host.
Feeder Contrast with hitchhiker and internal feeder.
FAA Federal Aviation Administration
FIFRA Federal Insecticide, Fungicide, and Rodenticide Act
g grams
GI gastrointestinal
HDT highest dose tested
Hgb hemoglobin
HHS U.S. Department of Health and Human Services
Hitchhiker A pest transported by chance and not found inhabiting its host. Contrast
with external feeder.
i.m. intramuscular
Internal A pest that normally inhabits the inside or inner part of its host.
Feeder Contrast with external feeder.
i.p. intraperitoneal
Glossary
Acronyms, Abbreviations, and Terms
9-1-2 Treatment Manual 10/2002-04
PPQ
i.v. intravenous
kg kilogram
L liter
LC50 Lethal Concentration 50; dose lethal to 50% of the animals
LCLO Lethal Concentration Low; the lowest concentration causing death
LD50 Lethal Dose 50; dose lethal to 50% of the animals
LDLO Lethal Dose Low; the lowest dose at which death occurred
LDT lowest dose tested
LEL lower exposure limit, or lowest-effect level
LOAEL lowest-observed-adverse-effect-level
m meter
MED minimum effective dose
mg milligram
mg/kg milligrams per kilogram
mg/L milligrams per liter
mmHg millimeters of mercury; a measure of pressure
MOE Margin of Exposure
MOS Margin of Safety
MSDS Material Safety Data Sheet
MTD maximum tolerated dose
MTL median threshold limit
NFPA National Fire Prevention Association
ng nanogram
NIOSH National Institute for Occupational Safety and Health
NMRAL National Monitoring and Residue Analysis Laboratory
NOAEL no-observed-adverse-effect level
NOEL no-observed-effect level
NTP National Toxicology Program
OIC Officer-in-Charge
OSHA U.S. Occupational Safety and Health Administration
p.o. per os (by mouth)
PEL permissible exposure limit
PHS U.S. Public Health Service
ppb parts per billion
ppm parts per million
PPQ Plant Protection and Quarantine
RBC red blood cell(s)
RfD Reference Dose
RfDi Inhalation Reference Dose
RfDo Oral Reference Dose
s.c. subcutaneous
STEL short-term exposure limit
Glossary
Acronyms, Abbreviations, and Terms
10/2002-04 Treatment Manual 9-1-3
PPQ
TLV threshold limit value
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
航空资料9(138)