NOTE: Tape a thermocouple adjacent to the bond area to aid in indicating bond line temperature.
(b)
Set an infrared lamp, heat clamp or blower directly over the base. Position lamp about 4 to 6 inches from base.
(c)
Adjust blower, heat clamp or infrared lamp to give a bond line temperature as indicated in following chart.
Temp (°F) Minimum Cure Time
60 48 hours 75 24 hours 130 3 hours
CAUTION: DO NOT CURE SEALANT BELOW 60°F OR ABOVE 130°F.
(d)
Cure for time shown below. Cure is complete when sealant cannot be indented with knife.
(e)
Check that fillet has durometer reading of 30 before returning airplane to service.
(7)
Fill any visible gaps or cracks in fillet or between base and airplane surface with fresh sealant.
(8)
Check static discharger base.
(a)
When sealant is fully cured and cooled to between 70 and 80°F, check for cracks in sealant fillet between base and airplane surface. Any crack is cause for rejection.
(b)
Check electrical bond between discharger bases and aluminum structure per 20-22-01. Resistance for newly installed dischargers should not exceed:
0.01 ohms for dischargers mounted on metal panels.
0.10
ohms for dischargers mounted on fiberglass laminate or composite panels coated with aluminum flame spray and dischargers mounted on aluminum coated glass fabric.
1.0
ohms for dischargers mounted on composite panels without aluminum coating.
WARNING: MAKE SURE THAT THE BONDING METER IS RESISTANT TO EXPLOSION. IF NOT IT IS POSSIBLE THAT AN EXPLOSION OR FIRE CAN OCCUR.
501
May 01/03 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. 23-61-0 Page 407
(9) Install Static Discharger
NOTE: Before installing new discharger, check general condition of discharger. Reject discharger with blunt or bent pins.
(a)
Fit static discharger on mounting base.
(b)
Hold discharger in place and tighten setscrew.
(c)
Check security of discharger on mounting base.
(d)
Use these precautions for possible fuel vapors when you use a megohmeter:
WARNING: USE THE PRECAUTIONS THAT FOLLOW WHEN YOU USE A MEGOHMMETER. IF YOU DO NOT USE PRECAUTIONS, THEN IT IS POSSIBLE THAT AN EXPLOSION OR FIRE CAN OCCUR.
1) Use the Quadtech 1863 megohmmeter or equivalent meter with a 500 VDC test voltage and a maximum 5 milliampeter short circuit current. 2) Do not use a megohmmeter at these locations: a) Area adjacent to or below a wing fuel tank vent, five foot (1.524 meters) diameter column, from vent to ground. b) Zero to 18 inches (457 mm) above the ground in the area around the airplane.
3) Make sure that: a) Area is well ventilated. b) Metal workstands are grounded. c) Megohmmeter is plugged into a grounded receptacle. d) Megohmmeter is insulated from metal work stands.
(e) Measure resistance between the end of discharger tip and the discharge base using a megohmmeter of at least 500 volts. To make a good surface contact with the end of the discharger tip, wet a paper towel, cotton cloth or sponge with tap water and place in contact with entire surface of end of discharger tip. Place megohmmeter leads on base and on wet material at end of tip. If reading is high, verify that the wet material is adhering to the meter lead and to the end of the discharger tip. Add more water if necessary and measure again. Take lowest reading. Check that measured resistance is within a reading of 6-100 megohms for tip and trailing edge dischargers.
(10) Refinish bared surface of airplane to match surrounding area.
NOTE: Do not paint any part of dischargers or retainers.
C. Put the airplane back to its usual condition
(1) Put the hydraulic systems for the flight control surfaces back to the usual condition (Ref 27-11-0 MP, 27-21-0 MP, 27-31-0 MP).
502
23-61-0 Page 408 BOEING PROPRIETARY - Copyright . - Unpublished Work - See title page for details. May 01/03
DECOUPLED STATIC DISCHARGER - INSPECTION/CHECK
1. General
A. Decoupled static dischargers should be carefully checked on a periodic basis since failure to do so will impair radio reception and cause undue static interference.
2. Equipment and Materials
A. Megohmmeter (500 VDC Test Voltage, maximum 5 milliampere short circuit current) -Quadtech 1863 megohmmeter (or equivalent).
B. Bonding Meter (Ref 20-22-01)
3. Periodic Check of Decoupled Static Discharger
A. Prepare for check of Static Dischargers.
(1)