(2)
Remove the screws (5).
(3)
Put the antenna (4) away from the fuselage (1).
(4)
Disconnect the coaxial connector (2).
(5)
Remove the antenna (4).
(6)
Put blanking caps on the disconnected coaxial connectors (2) and (3).
(7)
Remove and discard the O-ring seal (6).
1EFF : ALL 1 34-51-11Page 402 1 1 Feb 01/98 1 1 1CES 1
DME Antenna
Figure 401/TASK 34-51-11-991-002
1EFF : ALL 1 34-51-11 Page 403
1 1 Feb 01/98
1 1
1CES 1
TASK 34-51-11-400-002
Installation of the DME Antenna (3SD1, 3SD2)
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL MATERIALS
_______ ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
WARNING : DO NOT GET THE COMPOUND ON YOUR SKIN.
_______ IF YOU DO:
-RUB IT OFF IMMEDIATELY WITH A CLEAN CLOTH
-WASH THE SKIN WITH SOAP AND RINSE WITH CLEAN WATER.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific lint-free cloth No specific masking tape No specific nonmetallic scraper
1EFF : ALL 1 34-51-11Page 404 1 1 Feb 01/98 1 1 1CES 1 B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-013 D TV-53-3507/73 RELEASE AGENT (OBSOLETE USE 05-013A) (Ref. 20-31-00)
Material No. 07-001B
ELECTRICAL BONDING COATING (BLUE COLOR)
(Ref. 20-31-00)
Material No. 09-016 USA MIL-PRF-81733D TYPE II CLASS B
CORROSION INHIBITING FILLET CONSISTENCY
(Ref. 20-31-00)
Material No. 09-019 USA AMS 3267/3
LOW ADHESION CORROSION INHIBITING SEALANT
(Ref. 20-31-00)
R Material No. 11-003 USA ASTM D 740 METHYL-ETHYL-KETONE (Ref. 20-31-00) Material No. 16-003 F ASNB70720 COATING (OBSOLETE USE 16-021) (Ref. 20-31-00)
C. Expendable Parts
-------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
O-ring seal 34-51-11 01 -010
D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-28-00-912-005 Electrical Bonding of Antennas With Conductive Bolts. 34-51-00-710-001 Operational Test of the DME 34-51-00-720-001 Functional Test of the DME 51-76-11-300-001 Repair of the Sealing 34-51-11-991-002 Fig. 401
1EFF : ALL 1 34-51-11Page 405 1 1 Nov 01/04 1 1 1CES 1 1EFF : ALL 1 34-51-11Page 406 1 1 Nov 01/04 1 1 1CES 1
3. Job Set-up__________
Subtask 34-51-11-865-053
A. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------FOR 3SD1 49VU NAV/DME/1 1SD1 G14 FOR 3SD2 121VU COM NAV/DME/2 1SD2 K06
4. Procedure_________
(Ref. Fig. 401/TASK 34-51-11-991-002)
R R R R R WARNING : YOU MUST OBEY ALL THE SAFETY PROCEDURES WHEN YOU DO WORK IN OR_______ NEAR A FUEL TANK. IF YOU DO NOT OBEY THE SAFETY PROCEDURES, THERE IS A RISK OF: - DEATH OR INJURY TO PERSONS - DAMAGE TO THE AIRCRAFT OR OTHER EQUIPMENT.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE SPECIAL_______ MATERIAL. THIS MATERIAL IS DANGEROUS.
Subtask 34-51-11-420-050
A. Installation of the DME Antenna