R **ON A/C 106-149, 211-299, 301-399, 401-499,
Subtask 31-33-00-710-062-A
A. Do the FDIU Fault Monitoring via CFDS Test
(Ref. Fig. 502A/TASK 31-33-00-991-002-A)
NOTE : You can print the available information only when the PRINT>
____
indication shows on the MCDU screen.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the control panel 21VU: On the control panel 21VU:
-Push the GND/CTL pushbutton. - The blue indicator light 'ON' comes on.
2. On the MCDU: On the MCDU display:
1EFF : ALL 1 31-33-00Page 520 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- Push the MCDU MENU mode key. - The MCDU MENU page comes into view.
- Push the line key adjacent to - The CFDS page comes into view.
the <CFDS indication.
- Push the line key adjacent to - The SYSTEM REPORT/TEST page comes
the <SYSTEM REPORT/TEST into view.
indication.
- Push the line key adjacent to - The INST page comes into view.
the INST> indication.
- Push the line key adjacent to - The DFDRS page comes into view.
the <FDIU indication.
- Push the line key adjacent to - The DFDRS LRU IDENTIFICATION page
the <LRU IDENT indication. comes into view.
- The name of the LRU, the hardware P/N
and the software P/N shows.
- Push the line key adjacent to - The DFDRS page comes into view.
the <RETURN indication.
- Push the line key adjacent to - The DFDRS TEST page comes into view.
the TEST> indication.
- Push the line key adjacent to - The message TEST OK shows.
the <START TEST indication.
- Push the line key adjacent to - The DFDRS page comes into view.
the <RETURN indication.
- Push the MCDU MENU mode key. - The MCDU MENU page comes into view.
3. On the control panel 21VU: On the control panel 21VU:
- Push the GND/CTL push button. - The blue indicator light 'ON' goes
off.
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-33-00Page 521 1 1 Aug 01/05 1 1 1CES 1
DFDR-Test
Figure 502A/TASK 31-33-00-991-002-A12 (SHEET 1)
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-33-00Page 522 1 1 Aug 01/05 1 1 1CES 1
DFDR-Test
Figure 502A/TASK 31-33-00-991-002-A22 (SHEET 2)
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-33-00Page 523 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
5. Close-up
________ Subtask 31-33-00-862-054
A. Put the aircraft back to its initial configuration.
(1)
De-energize the CFDS (Ref. TASK 31-32-00-860-008).
(2)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
(3)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
R 1EFF : ALL 1 31-33-00Page 524 1 1 Aug 01/05 1 1 1CES 1
TASK 31-33-00-710-007 Operational Test of the DFDR
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 31-32-00-860-008 Procedure to Get Access to the SYSTEM
REPORT/TEST/INST Page 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure
3. Job Set-up
__________ Subtask 31-33-00-861-055