The MDDU READY indication shows.
On the Data Loading Selector display:
-
The FDR SYS NOT SELECTED indication shows.
R 1EFF : 106-149, 229-299, 303-399, 401-499, 1 31-33-00Page 209 1 1 Aug 01/05 1 1 1CES 1
**ON A/C 211-228, 301-302,
Subtask 31-33-00-710-075-A
A. FDIMU-FDIU Software Load Procedure
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the overhead panel, on the Data Loading Selector:
-Put the data loading selector ON/OFF switch to the ON position.
-
Push the NEXT or PREV key until the FDR SYS NOT SELECTED indication shows on the display.
-
Push the SEL CTL key.
On the Center Pedestal, on the MDDU:
-Open the floppy disk access door.
-Put the software disk 10TV1 (FDIU-Software) into the MDDU.
On the Data Loading Selector display:
-
The DB/N:XXXXXXXX and PUSH NEXT/PREVindications show.
-
The FDR SYS NOT SELECTED indicationshows.
-
The FDR SYS SELECTED indication shows.
On the MDDU display:
-
The MDDU READY indication shows.
-These indications show in a shorttime: READY, WAIT RESPONSE, TRANSF IN PROG.
NOTE : Dependently from the MDDU P/N it can show the BUS-number and the
____ file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the
progress of the data loading.
-Wait until the TRANSF COMPLETE indication comes on.
-Push the EJECT button and remove the software disk 10TV1.
-Close the floppy disk access door.
-
The TRANSF COMPLETE indication showsafter the load procedure is completed correctly.
-
The MDDU READY indication shows.
1EFF : 211-228, 301-302, 1 31-33-00Page 210 1 1 Aug 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------On the Data Loading Selector panel: On the Data Loading Selector display:
-Push the SEL CTL key. - The FDR SYS NOT SELECTED indication shows.
-Set the ON/OFF switch to OFF. R **ON A/C 106-149, 211-299, 301-399, 401-499,
5. Close-up
________
Subtask 31-33-00-710-076
A. Do the test of the FDIMU (Ref. TASK 31-36-00-740-012).
Subtask 31-33-00-860-056
B. Put the system back to the serviceable condition.
(1) De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002)
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-33-00Page 211 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-105,
TASK 31-33-00-710-008
Optical QAR Software Load Procedure
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific access platform
No specific Bootable Application Disk
No specific Data Disk
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-33-00-710-005 Operational Test of the QAR 52-41-00-010-002 Open the Avionics Compartment Doors for Access 52-41-00-410-002 Close the Avionics Compartment Doors after Access