monitoring operation of recorded data,
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-33-00Page 93 1401-499, 1Aug 01/05 1 1 1CES 1
-monitoring operation of the power supply circuitry. **ON A/C ALL
8. Test BITE
_________
A. Conditions of Power-Up Test Initialization
(1)
How long the computer must be de-energized:
-1 second
(2)
A/C configuration:
-A/C on ground and engines stopped
B. Progress of Power-up Test
(1)
Duration:
-25 seconds max.
(2)
Cockpit repercussions directly connected with power-up test accomplishment (some other repercussions may occur depending on the A/C configuration but these can be ignored):
-ECAM warnings: "RECORDER FDIU FAULT" is shown for 3 seconds.
C. Results of Power-up Test
(1)
Test passed:
-None
(2)
Test failed:
-ECAM warning:
"RECORDER FDIU FAULT"
1EFF : ALL 1 31-33-00Page 94 1 1 Aug 01/05R 1 1 1CES 1
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
D. DFDRS Failure Messages
-----------------------------------------------------------------------------| ATA - NO | Name of Failure | EXT/INT | Class | |------------|-------------------------------------------|-----------|--------| | 31-33-55 | DFDR | INT | II | | | | | | | 31-33-34 | FDIU | INT | II | | | | | | | 31-33-52 | QAR (if installed) | INT | II | | | | | | | 31-33-52 | QAR TAPE LOW (if installed) | INT | II | | | | | | | 31-33-16 | ACCELEROMETER | INT | II | | | | | | | 31-33-55 | DFDR PLAYBACK | INT | III | | | | | | | 31-33-34 | NO AC IDENT CODE | INT | III | | | | | | | 31-21-34 | NO CLOCK DATA | EXT | III | | | | | | | 31-32-34 | NO CFDS DATA | EXT | III | | | | | | | 31-55-34 | NO SDAC 1 DATA | EXT | III | | | | | | | 31-55-34 | NO SDAC 2 DATA | EXT | III | | | | | | | 31-53-34 | NO FWC 1 DATA | EXT | III | | | | | | | 31-53-34 | NO FWC 2 DATA | EXT | III | | | | | | | 31-62-34 | NO DMC 1 DATA | EXT | III | | | | | | | 31-62-34 | NO DMC 2 DATA | EXT | III | | | | | | | 32-42-34 | NO BSCU 1 DATA | EXT | III | | | | | | | 32-42-34 | NO BSCU 2 DATA | EXT | III | | | | | | | 27-95-34 | NO FCDC 1 DATA | EXT | III | | | | | | | 27-95-34 | NO FCDC 2 DATA | EXT | III | -----------------------------------------------------------------------------
1EFF : 001-049, 051-099, 101-105, 151-158, 1 31-33-00Page 95 1201-209, 1May 01/05 1 1 1CES 1R **ON A/C 106-149, 211-299, 301-399, 401-499,
D. DFDRS Failure Messages
-----------------------------------------------------------------------------| ATA - NO | Name of Failure | EXT/INT | Class | |------------|-------------------------------------------|-----------|--------| | 31-33-55 | DFDR (1TU) | INT | II | | | | | | | 31-36-34 | FDIMU (10TV) | INT | II | | | | | | | 31-33-52 | QAR (3TU) (if installed) | INT | II | | | | | | | 31-33-52 | QAR TABLE LOW (if installed) | INT | II | | | | | | | 31-33-16 | ACCELEROMETER (6TU) | INT | II | | | | | | | 31-33-55 | DFDR PLAYBACK (1TU) | INT | III | | | | | | | 31-33-34 | NO AC IDENT CODE (14TU) | INT | III | | | | | | | 31-21-34 | CLOCK(1FS)/FDIMU(10TV) | EXT | III | | | | | | | 45-13-34 | CFDIU(1TM)/FDIMU(10TV) | EXT | III | | | | | | | 31-55-34 | SDAC(1WV1)/FDIMU(10TV) | EXT | III | | | | | | | 31-55-34 | SDAC2(1WV2)/FDIMU(10TV) | EXT | III | | | | | | | 31-53-34 | FWC1(1WW1)/FDIMU(10TV) | EXT | III | | | | | | | 31-53-34 | FWC2(1WW2)/FDIMU(10TV) | EXT | III | | | | | | | 31-62-34 | DMC1(1WT)/FDIMU(10TV) | EXT | III | | | | | | | 31-62-34 | DMC2(1WT)/FDIMU(10TV) | EXT | III | | | | | | | 31-42-34 | BSCU1(3GG)/FDIMU(10TV) | EXT | III | | | | | | | 31-42-34 | BSCU2(3GG)/FDIMU(10TV) | EXT | III | | | | | | | 27-95-34 | FCDC1(1CE1)/FDIMU | EXT | III | | | | | | | 27-95-34 | FCDC2(1CE1)/FDIMU | EXT | III | -----------------------------------------------------------------------------
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-33-00Page 96 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 159-199, 210-210,
D. DFDRS Failure Messages
-----------------------------------------------------------------------------| ATA - NO | Name of Failure | EXT/INT | Class | |------------|-------------------------------------------|-----------|--------| | 31-33-55 | DFDR (1TU) | INT | II | | | | | | | 31-33-34 | FDIU (2TU) | INT | II | | | | | | | 31-33-52 | QAR (3TU) (if installed) | INT | II | | | | | | | 31-33-52 | QAR TABLE LOW (if installed) | INT | II | | | | | | | 31-33-16 | ACCELEROMETER (6TU) | INT | II | | | | | | | 31-33-55 | DFDR PLAYBACK (1TU) | INT | III | | | | | | | 31-33-34 | NO AC IDENT CODE (14TU) | INT | III | | | | | | | 31-21-34 | CLOCK(1FS)/FDIU(2TU) | EXT | III | | | | | | | 45-13-34 | CFDIU(1TM)/FDIU(2TU) | EXT | III | | | | | | | 31-55-34 | SDAC(1WV1)/FDIU(2TU) | EXT | III | | | | | | | 31-55-34 | SDAC2(1WV2)/FDIU(2TU) | EXT | III | | | | | | | 31-53-34 | FWC1(1WW1)/FDIU(2TU) | EXT | III | | | | | | | 31-53-34 | FWC2(1WW2)/FDIU(2TU) | EXT | III | | | | | | | 31-62-34 | DMC1(1WT)/FDIU(2TU) | EXT | III | | | | | | | 31-62-34 | DMC2(1WT)/FDIU(2TU) | EXT | III | | | | | | | 31-42-34 | BSCU1(3GG)/FDIU(2TU) | EXT | III | | | | | | | 31-42-34 | BSCU2(3GG)/FDIU(2TU) | EXT | III | | | | | | | 27-95-34 | FCDC1(1CE1)/FDIU(2TU) | EXT | III | | | | | | | 27-95-34 | FCDC2(1CE1)/FDIU(2TU) | EXT | III | -----------------------------------------------------------------------------