II. INSPECTION OPTIONS - DTR CHECK FROM F-33B Frames between BS 360 and BS 540 just below stringer S-17 at crease Beam web to frame attach clips.
(1) Web
(Internal) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-48 and 53-10-49). 2.0 elapsed hours and 2.0 manhours are required to accomplish these inspections.
Access: Remove main cabin equipment, side wall panels S2082, S2084, floor panels S2085 and insulation, as required.
Zone(s): 107.
(2)
Fail-Safe Chord
(Internal) From Direction 2, using visual inspection methods.
Access: Same as II. (1).
Zone(s): Same as II. (1).
(3)
Inner Chord
(Internal) From Direction 3, using visual inspection methods.
Access: Same as II. (1).
Zone(s): Same as II. (1).
(4)
Inner Chord
(Internal) From Direction 4, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-55). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
III. INSPECTION OPTIONS - DTR CHECK FORM F-33C Frames between BS 360 and BS 540 from stringers S-13 to S-17.
(1) Inner Chord and Web
(Internal) From Direction 1, using visual inspection methods.
Access: Same as II. (1).
Zone(s): Same as II. (1).
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
(2) Inner Chord and Web
(Internal) From Direction 4, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-59). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Same as II. (1).
Zone(s): Same as II. (1).
(3)
Fail-Safe Chord (Internal) From Direction 2, using visual inspection methods.
Access: Same as II. (1).
Zone(s): Same as II. (1).
(4)
Fail-Safe Chord
(Internal) From Direction 3, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-59). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Same as II. (1).
Zone(s): Same as II. (1).
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
N96772
F-34 - SHEAR TIED FRAMES BETWEEN BS 727 AND 1016
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
N96809
F-34 - SHEAR TIED FRAMES BETWEEN BS 727 AND 1016 (Continued)
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
F-34 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300/400/500 补充结构检查文件 SUPPLEMENTAL STRUCTURAL INSPECTION DOCUMENT 1(64)