8.2 FUSELAGE SSI INFORMATION D6-82669 Original
F-10 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: FORWARD CARGO DOOR CUTOUT S53-22-E C53-100-01 C53-202-01 C53-202-03 I.(1) II.(1) 0.5 14 0.5 7
I. INSPECTION OPTIONS - DTR CHECK FORM F-10A
Around cutout (within "Area A" and "Area C" as shown on the illustration pages) except at the seal ramp which is covered by F-10C (Ref. Service Bulletin 737-53-1051 in Section 9.0).
(1) Reinforcement (Bear) Strap
(Internal) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-65).
Access: Open door 4404. Remove lower sill corner scuff plates.
Zone(s): 200.
(2) Reinforcement (Bear) Strap
(External) From Direction 2, including fastener locations, using visual inspection methods.
Access: Open door 4404.
Zone(s): 208.
II. INSPECTION OPTIONS - DTR CHECK FORM F-10B Around cutout (within "Area B" and "Area C" as shown on the second illustration page).
(1) Frames, Sills, Reinforcement (Bear) Strap, Chords and Skin
(Internal) From Direction 4, including fastener locations, using visual inspection methods and at specified locations using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-33).
Access: Open door 4404. Remove lining and remove or displace insulation blankets as required.
Zone(s): 208.
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
III. INSPECTION OPTIONS - DTR CHECK FORM F-10C Around cutout where area is obstructed by sealant (within "Area A" shown on the first illustration page).
(1) Reinforcement (Bear) Strap
(Internal) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-65).
Access: Same as I. (1).
Zone(s): 200.
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
D6-82669 8.2 FUSELAGE SSI INFORMATION
Original
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
MODEL-SERIES
ITEM:
F-10C
DTR CHECK FORM
737-300/-400/-500
TITLE: Forward Cargo Door Cutout
LOCATION: AREA A
WHERE OBSTRUCTED BY SEAL RAMP
DTR 20 10 5 2 1 .5 LFEC 1
.2 .1 .03.05 NOTES: .1 .2 .5 1 2 5 N (THOUSANDS OF FLIGHTS)
10 20
50
100
OPERATOR(S)
NO. OF ELIGIBLE A/C
EXAMPLE
STRUCTURE AND INSPECTION DETAILS
INSPECTION PROGRAM DETAILS
STRUCTURE
DETAIL TASK REFERENCE DIREC. CHECK LEVEL METHOD %PHASE Ro FREQUENCY F-FLIGHTS N= 100F/R o
ZONE
208
DAMAGE 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300/400/500 补充结构检查文件 SUPPLEMENTAL STRUCTURAL INSPECTION DOCUMENT 1(47)