8.2 FUSELAGE SSI INFORMATION D6-82669 Original
MODEL-SERIES
ITEM:
F-14B
DTR CHECK FORM
CUTOUT, FORWARD ENTRY
TITLE:
(WITH AIRSTAIRS)
AREA A, AREA B, AND AREA C
LOCATION:
20
10
5
2
DTR
1
.5
.2
.1
.03.05 .1 .2 .5 1 2 5 10 20 50 100
N (THOUSANDS OF FLIGHTS)
NOTES:
737-300/-400/-500
OPERATOR(S)
NO. OF ELIGIBLE A/C
EXAMPLE
STRUCTURE AND INSPECTION DETAILS
LEAD CRACK: FRAME CHORD
2
1 GENERAL VISUAL INSPECTION IN AREA B; DETAILED INSPECTION IN AREA C; HFEC
OR LFEC INSPECTION (AS SPECIFIED IN NDT DOCUMENT) OF OUTER CHORDS IN AREA A
WHERE FRAME WEB IS NOT VISIBLE; HFEC INSPECTION OF INNER CHORDS IN AREA C
AT FRAME-TO-SILL INTERSECTIONS.
2 INNER CHORD NOT SHOWN
3 WITH AIRSTAIRS DOOR
STRUCTURE DETAIL TASK REFERENCE INSPECTION PROGRAM DETAILS DIREC. CHECK LEVEL METHOD %PHASE Ro FREQUENCY F-FLIGHTS N = 100F/Ro
FRAMES, SILLS, BEAR STRAP AND SKIN 3 4C 1 100 12000 12000
DAMAGE
DETECTION
PERIOD
DTR
N FLIGHTS
o
42400 10.2
F14B_PDF
FUEL LEAK DTR N/A
ENGR. C. KATYAL 2/18/99 REVISED
TOTAL DTR 10.2
CHECK R. JOCHUM2/18/99
APPR.
REQUIRED DTR
APPR.
Original D6-82669 8.2 FUSELAGE SSI INFORMATION THIS PAGE INTENTIONALLY LEFT BLANK
8.2 FUSELAGE SSI INFORMATION D6-82669 BLANK
N96967
F-15A - FORWARD GALLEY DOOR CUTOUT
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
N96969
F-15B - FORWARD GALLEY DOOR CUTOUT (Continued)
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
F-15 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: FORWARD GALLEY DOOR CUTOUT S53-22-A C53-100-01 C53-107-01 I.(2) II.(1) 0.5 10 0.5 5
I. INSPECTION OPTIONS - DTR CHECK FORM F-15A Around door cutout (within "Area A” and “Area C" as shown on the illustration pages).
(1)
Skin and Aft Reinforcement (Bear) Strap
(External) From Direction 1, using visual inspection methods.
Access: Open door 4701.
Zone(s): 100, 200, 107, 205.
(2)
Reinforcement (Bear) Strap and Skin
(Internal) From Direction 2, at specified locations, using LFEC (Ref. NDT Manual D6-37239,Part 6, 53-10-69) and at specified locations, using HFEC (Ref. NDT Manual D6-37239,Part 6, 53-10-08).
1.0 elapsed hour and 2.0 manhours are required to perform these NDT inspections.
Access: Open door 4701. Remove lower sill corner scuff plates.