Access: Same as I. (1).
Zone(s): Same as I. (1).
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
(2) Chord
(Internal) From Direction 2, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-06). 1.5 elapsed hours and 1.5 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
(3) Chord
(Internal) From Direction 3, at specified locations, using Ultrasonic (Ref. NDT Manual D6-37239, Part 4,
53-20-01). 1.25 elapsed hours and 2.25 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
Original D6-82669 8.2 FUSELAGE SSI INFORMATION THIS PAGE INTENTIONALLY LEFT BLANK
8.2 FUSELAGE SSI INFORMATION D6-82669 BLANK
N96497
F-29 - FUSELAGE BULKHEAD BS 727
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
F-29 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: FUSELAGE BULKHEAD BS 727 S53-16-A C53-202-01 C53-208-01 I.(1) 6 3
I. INSPECTION OPTIONS - DTR CHECK FORM F-29A
Body Station 727 bulkhead, stringer S-18 to stringer S-25, except at horizontal stringer and vertical stiffener locations where F-29B applies.
(1) Fail-Safe Chord, Web, and Doubler
(Internal) From Direction 1, including fastener locations, using visual inspection methods.
Access: Access through aft cargo door 4504 and through forward portion of aft cargo compartment. Remove lining S2181, remove access panels 1540, 1541, 1542, 1543, and displace insulation blankets as required.
Zone(s): 218.
(2) Fail-Safe Chord
(Internal) From Direction 2, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-68). 1.0 elapsed hour and 1.0 manhour are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
II. INSPECTION OPTIONS - DTR CHECK FORM F-29B
Body Station 727 bulkhead, stringer S-18 to stringer S-25, at horizontal stringer and vertical stiffener
locations.
(1) Fail-Safe Chord, Web, and Doubler
(Internal) From Direction 1, including fastener locations, using visual inspection methods.
Access: Same as I. (1).
Zone(s): Same as I. (1).