8.2  FUSELAGE SSI INFORMATION D6-82669  Original

(2)
Fail-Safe Chord (Internal) From Direction 2 at specified locations, using HFEC (Ref. D6-37239, Part 6, 53-10-68).

0.75 elapsed hour and 0.75 manhours are required to accomplish these inspections.
Access: Same as I. (1).
Zone(s): Same as I. (1).


(3)
Fail-Safe Chord


(Internal) From Direction 5, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-25). 1.5 elapsed hours and 1.5 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
Original D6-82669 8.2  FUSELAGE SSI INFORMATION


8.2  FUSELAGE SSI INFORMATION D6-82669 Original


D6-82669 8.2  FUSELAGE SSI INFORMATION
Original

THIS PAGE INTENTIONALLY LEFT BLANK
8.2  FUSELAGE SSI INFORMATION D6-82669 BLANK


F-30 - FUSELAGE BULKHEAD BS 1016
Original D6-82669 8.2  FUSELAGE SSI INFORMATION


N98428
F-30 - FUSELAGE BULKHEAD BS 1016
8.2  FUSELAGE SSI INFORMATION D6-82669 Original

F-30  INSPECTION INSTRUCTIONS  REFERENCES  ACCESS MANHOURS 
MPD  CPCP  OTHERS  INSP  MHRS  ELPSD 
TITLE:  FUSELAGE BULKHEAD BS 1016  S53-07-A S53-27-F  C53-107-01 C53-202-01 C53-208-01 C53-701-01 

I.  INSPECTION OPTIONS - DTR CHECK FORM F-30A
From stringer S-3 to stringer S-7, stringer S-13 to stringer S-14, stringer S-15 to stringer S-16, stringer
S-20 to stringer S-22, stringer S-24 to stringer S-25, and stringer S-26 to stringer S-27, left and right.

(1)  "Y" Frame
(External) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-16). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Stabilizer trim access door 3701.
Zone(s): 701.
II.  INSPECTION OPTIONS - DTR CHECK FORM F-30B 1016 Bulkhead Web at “Y” Chord.
(1)  “Y” Chord
(External) From Direction 2, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-63). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Remove galley, lavatory, floor panels and displace insulation blankets as required.
Zone(s): 108, 220.
Original  D6-82669 8.2  FUSELAGE SSI INFORMATION

III.  INSPECTION OPTIONS - DTR CHECK FORM F-30C Hidden row of fasteners on radial web splice from center ring to "Y" frame.
(1) Web
(External) From Direction 1 aft, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-41).

2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).

IV.  INSPECTION OPTIONS - DTR CHECK FORM F-30D Open row of fasteners on radial web splice from center ring to "Y" frame.
 