8.2 FUSELAGE SSI INFORMATION D6-82669 Original
(2)
Fail-Safe Chord (Internal) From Direction 2 at specified locations, using HFEC (Ref. D6-37239, Part 6, 53-10-68).
0.75 elapsed hour and 0.75 manhours are required to accomplish these inspections.
Access: Same as I. (1).
Zone(s): Same as I. (1).
(3)
Fail-Safe Chord
(Internal) From Direction 5, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-25). 1.5 elapsed hours and 1.5 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
D6-82669 8.2 FUSELAGE SSI INFORMATION
Original
THIS PAGE INTENTIONALLY LEFT BLANK
8.2 FUSELAGE SSI INFORMATION D6-82669 BLANK
F-30 - FUSELAGE BULKHEAD BS 1016
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
N98428
F-30 - FUSELAGE BULKHEAD BS 1016
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
F-30 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: FUSELAGE BULKHEAD BS 1016 S53-07-A S53-27-F C53-107-01 C53-202-01 C53-208-01 C53-701-01
I. INSPECTION OPTIONS - DTR CHECK FORM F-30A
From stringer S-3 to stringer S-7, stringer S-13 to stringer S-14, stringer S-15 to stringer S-16, stringer
S-20 to stringer S-22, stringer S-24 to stringer S-25, and stringer S-26 to stringer S-27, left and right.
(1) "Y" Frame
(External) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-16). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Stabilizer trim access door 3701.
Zone(s): 701.
II. INSPECTION OPTIONS - DTR CHECK FORM F-30B 1016 Bulkhead Web at “Y” Chord.
(1) “Y” Chord
(External) From Direction 2, at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-63). 2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Remove galley, lavatory, floor panels and displace insulation blankets as required.
Zone(s): 108, 220.
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
III. INSPECTION OPTIONS - DTR CHECK FORM F-30C Hidden row of fasteners on radial web splice from center ring to "Y" frame.
(1) Web
(External) From Direction 1 aft, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-41).
2.0 elapsed hours and 2.0 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
IV. INSPECTION OPTIONS - DTR CHECK FORM F-30D Open row of fasteners on radial web splice from center ring to "Y" frame. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300/400/500 补充结构检查文件 SUPPLEMENTAL STRUCTURAL INSPECTION DOCUMENT 1(60)