• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-10-31 15:52来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

DETECTION
PERIOD

DTR

N FLIGHTS

o

BEAR STRAP 1 C LFEC 100 3000 3000 11900 11.0


FUEL LEAK DTR  N/A
ENGR.  CALZADILLA  5/4/99  REVISED 
CHECK  R. JOCHUM  5/18/99  TOTAL DTR  11.0 


APPR.

REQUIRED DTR

10

APPR.


D6-82669 8.2  FUSELAGE SSI INFORMATION
Original
F10C_PDF

THIS PAGE INTENTIONALLY LEFT BLANK
8.2  FUSELAGE SSI INFORMATION D6-82669 BLANK


N95472
F-11 - AFT CARGO DOOR CUTOUT
Original D6-82669 8.2  FUSELAGE SSI INFORMATION


N95579
F-11 - AFT CARGO DOOR CUTOUT (Continued)
8.2  FUSELAGE SSI INFORMATION D6-82669 Original

F-11  INSPECTION INSTRUCTIONS  REFERENCES  ACCESS MANHOURS 
MPD  CPCP  OTHERS  INSP  MHRS  ELPSD 
TITLE:  AFT CARGO DOOR CUTOUT  S53-22-F  C53-100-01 C53-202-01 C53-202-03  II.(1)  14  7 

I.  INSPECTION OPTIONS - DTR CHECK FORM F-11A
Around cutout (within "Area A" and "Area C" as shown on the illustration pages) except at the seal ramp which is covered by F-11C.
(1) Reinforcement (Bear) Strap
(Internal) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-65).
Access: Open door 4504.  Remove lower sill corner scuff plates.
Zone(s): 200.
(2) Reinforcement (Bear) Strap
(External) From Direction 2, including fastener locations, using visual inspection methods.

Access: Open door 4504.
Zone(s): 218.

II.  INSPECTION OPTIONS - DTR CHECK FORM F-11B Around cutout (within "Area B" and "Area C" as shown on the second illustration page).
(1) Frames, Sill, Reinforcement (Bear) Strap, Chords and Skin
(Internal) From Direction 4, including fastener locations, at specified locations using visual inspection methods, at specified locations using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-21).
Access: Open door 4504.  Remove lining and remove or displace insulation blankets as required.
Zone(s): 218.
Original  D6-82669 8.2  FUSELAGE SSI INFORMATION

III.  INSPECTION OPTIONS - DTR CHECK FORM F-11C Around cutout where area is obstructed by seal ramp (within "Area A" as shown on the first illustration page).
(1) Reinforcement (Bear) Strap
(Internal) From Direction 1, at specified locations, using LFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-65).
Access: Same as I. (1)
Zone(s): 200.

8.2   FUSELAGE SSI INFORMATION D6-82669 Original


Original D6-82669 8.2  FUSELAGE SSI INFORMATION


8.2  FUSELAGE SSI INFORMATION D6-82669 Original


Original D6-82669 8.2  FUSELAGE SSI INFORMATION THIS PAGE INTENTIONALLY LEFT BLANK
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300/400/500 补充结构检查文件 SUPPLEMENTAL STRUCTURAL INSPECTION DOCUMENT 1(48)