TOTAL DTR 7.6
CHECK
APPR.
REQUIRED DTR
6
APPR.
D6-82669 8.2 FUSELAGE SSI INFORMATION Original
PAGE F-31.5
F31B_PDF
THIS PAGE INTENTIONALLY LEFT BLANK
8.2 FUSELAGE SSI INFORMATION D6-82669 BLANK
N98152
F-32 - FUSELAGE BULKHEAD BS 1156
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
F-32 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: FUSELAGE BULKHEAD BS 1156 S53-20-A C53-701-01 I.(1) 0.5 0.5
I. INSPECTION OPTIONS - DTR CHECK FORM F-32 Hinge Support Beams at Hinge Pin, 1156 Bulkhead.
(1)
Hinge Support Beams and Doubler
(External) From Direction 1, using visual inspection methods.
Access: Through panel 9105, 9205 and removable inboard rib panel.
Zone(s): 701, 704.
(2)
Hinge Support Beams and Doubler
(External) From Direction 1, at specified locations using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-58). 0.25 elapsed hours and 0.25 manhours are required to accomplish this inspection.
Access: Same as I. (1).
Zone(s): Same as I. (1).
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
Original D6-82669 8.2 FUSELAGE SSI INFORMATION THIS PAGE INTENTIONALLY LEFT BLANK
8.2 FUSELAGE SSI INFORMATION D6-82669 BLANK
N96994
F-33 - SHEAR TIED FRAMES BETWEEN BS 360 AND 540
Original D6-82669 8.2 FUSELAGE SSI INFORMATION
N96930
F-33 - SHEAR TIED FRAMES BETWEEN BS 360 AND 540 (Continued)
8.2 FUSELAGE SSI INFORMATION D6-82669 Original
F-33 INSPECTION INSTRUCTIONS REFERENCES ACCESS MANHOURS
MPD CPCP OTHERS INSP MHRS ELPSD
TITLE: SHEAR TIED FRAMES BETWEEN BS 360 AND 540 S53-14-A S53-18-A S53-22-A S53-22-E S53-22-H S53-22-J S53-28-A S53-28-B S53-28-E S53-30-A S53-30-C S53-30-D C53-107-01 C53-202-01 C53-208-01
I. INSPECTION OPTIONS - DTR CHECK FORM F-33A Lower lobe frames between BS 360 and BS 540, stringer S-17L to S-17R.
(1) Inner Chord and Web
(Internal) From Direction 1, using visual inspection methods and at specified locations, using HFEC (Ref. NDT Manual D6-37239, Part 6, 53-10-66).
Access: Access doors 1103, 1201, 1601 (if installed), 3103, 3104, 3105, 3106, 4404. Remove cargo liner S2082, S2084, floor boards S2085, insulation as required and, if installed, auxiliary fuel tank.
Zone(s): 205, 208, 210.
(2) Fail-Safe Chord
(Internal) From Direction 2, using visual inspection methods.
Access: Same as I. (1).
Zone(s): Same as I. (1).
Original D6-82669 8.2 FUSELAGE SSI INFORMATION 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300/400/500 补充结构检查文件 SUPPLEMENTAL STRUCTURAL INSPECTION DOCUMENT 1(63)