28-11-00
ALL ú ú 01 Page 246 ú May 28/01
A
757 MAINTENANCE MANUAL
S 092-338
WARNING: MAKE SURE NO PERSONS ARE IN THE SLAT AREA WHEN YOU DO THE
_______ ACTIVATION OF THE LEADING EDGE SLAT PROCEDURE. IF PERSONS ARE IN THE SLAT AREA, INJURY CAN OCCUR.
(20)
Do the activation of the leading edge slat procedure (AMM 27-81-00/201).
S 862-340
(21)
Close these circuit breakers on the overhead circuit breaker panel, P6, and remove DO-NOT-CLOSE tags:
(a)
6F15, L FUEL OVRD PUMP
(b)
6F20, R FUEL OVRD PUMP
(c)
6H15, L AFT FUEL BOOST PUMP
(d)
6H17, R FWD FUEL BOOST PUMP
(e)
6H20, R AFT FUEL BOOST PUMP
(f)
6H23, L FWD FUEL BOOST PUMP
S 412-341
(22)
Connect these airplane batteries:
(a)
Main (AMM 24-31-01/401)
(b)
APU (AMM 24-31-03/401)
S 942-342
(23)
Remove all precautionary signs, and placards.
S 942-346
(24)
Remove all support equipment, stands, ladders, ropes etc.
TASK 28-11-00-112-344
4. Biocide Treatment of Fuel Tanks
_______________________________
A. General
(1)
Contamination in fuel tanks can result from the presence of micro-organisms which live and multiply at the interface of fuel and water. The most effective way to prevent this problem is to reduce, if not eliminate, the amount of water retained in the tanks. Fuel tanks can also be treated periodically with a biocide to minimize problems arising from microbial growth. If a tank inspection should disclose microbial growth, the tank must be cleaned (AMM 28-11-00/701).
B.
Consumable Materials
(1)
One of these two biocides: ú (a) G00452 Biocide fuel additive - Biobor JF
(b)
G02347 - Kathon FP 1.5 biocide, Rohm and Haas Company, Philadelphia, PA, (215) 592-3000
C.
References
(1)
AMM 12-11-01/301, Fuel Tank - Pressure Fueling
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-11-00
ALL ú ú 01.1 Page 247 ú Sep 28/02
A
757
MAINTENANCE MANUAL
D. Access
(1)
Location Zone
621 Leading Edge to Front Spar (Right)
E.
Fuel Tank Treatment
S 652-074
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 燃油 CHAPTER 28 - FUEL 1(57)