____ adjacent area. The total area should be at least twice as wide as the area you cover with sealant.
 (c)  
Rub dry with a clean, dry gauze pad.

 (d)  
Continue to clean and dry the surface until the dry gauze pad remains clean.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-11-00
 ALL  ú ú 01 Page 813 ú Sep 28/01

A

757 MAINTENANCE MANUAL
 S 218-067
 (7)  Make sure that all fasteners in the sealant repair area are installed and tightened unless you must install the fastener after you apply the faying surface sealant.
 NOTE: You cannot install and tighten most fasteners after you apply
____
 the sealant.

 S 378-037
 (8)  If the alodine metal surface treatment is worn or damaged, you must alodize the metal surface before you apply the new sealant or finish material.
 CAUTION: USE ONLY ALODINE 600 TO REPAIR ALUMINUM WING SURFACES.
_______ PRIMER ADHESION PROBLEMS CAN OCCUR IF OTHER ALODINE SOLUTIONS ARE USED.
 (a)  Apply an alodine layer to the surface with Alodine 600 (SRM 51-20-01).
 S 118-038
 (9)  Immediately before you apply the sealant, clean the surface with BMS 11-7 solvent and rub dry.
 NOTE:____Do not let the solvent dry on the surface. Do not touch the area with your fingers.
 G.  Prepare, Apply, and Cure Sealants and Corrosion Resistant Finish NOTE: It is very important to mix, use and keep sealants and corrosion
____ resistant finish correctly. You must follow approved procedures to prevent damage or injury.
 Fully mix all components per manufacturer's instructions. Do not mix sealants that you apply with a brush until you use them.
 Do not put thinners in the sealant.
 Keep the sealants covered when not in use.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-11-00
 ALL  ú ú 01 Page 814 ú May 20/98

A

757
MAINTENANCE MANUAL

 S 398-008
 CAUTION: DISCARD ALL SEALANT OR CORROSION RESISTANT FINISH THAT DOES NOT
_______ APPLY SMOOTHLY. INCORRECTLY APPLIED SEALANT OR TOPCOAT COULD CAUSE DAMAGE.
 (1)  
Storage of Sealant Compound that is not Mixed

 (a)  
Sealant that is not mixed and is kept for more than 6 months should be tested before you use it. A satisfactory check for outdated sealant is to mix a container of base material with its curing compound and, at room temperature, find the time necessary before a sample of the sealant you apply is not tacky. Compare this time with maximum permitted tack-free time given in the applicable sealant specification. If this time is more than the maximum permitted time, discard the sealant. You should keep sealant at temperatures between 50° to 80°F (10°C to 26.7°C).
 