NOTE: The display will show DISK INSERTED and then VOL:.
____ If the destination component is active, the display will then show the file, extension and the percent of the file transfer completed. If there is more than one file, the ADL will install the next file until all files are completed. If the software is on more than one disk, then the display will show CHANGE DISK or INSERT DISK when it is time to put in the subsequent disk.
NOTE: If TRANSFER FAIL shows, then the installation is
____ not completed. Open and close the circuit breaker for the component, and start the installation again.
IF READ/WRITE FAIL shows, then there is a problem with the disk. Open and close the circuit breaker for the component, and start the installation again. If the problem continues, then replace the disk.
(c) If CHANGE DISK or INSERT DISK shows on the display, wait approximately 10 seconds and then push the eject button.
NOTE: The installation can fail if you wait too long
____ before you remove and install disks.
1) Remove the disk from the disk drive. 2) Put the subsequent disk into the disk drive. 3) If there are more than two disks for the software
installation, then remove and install disks until COMPLETE or LOAD COMPLETE shows on the display.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-15-11
ALL ú ú 01 Page 213 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(d)
When COMPLETE or LOAD COMPLETE shows on the display, wait approximately 10 seconds and then push the eject button.
(e)
Remove the disk from the disk drive.
(f)
If there was a plastic protective disk in the disk drive before you installed software, then put it back in the disk drive.
S 862-026
(10)
Set the system select switch on the data loader control panel to the NORM position.
S 412-027
(11)
Close the front cover on the ADL.
S 742-028
(12)
Make sure that the correct software part numbers are installed in the component.
NOTE: The software installation task for the component has the
____ steps to do a software configuration check.
S 862-029
(13)
Remove electrical power (AMM 24-22-00/201).
F.
SFIM Airborne Data Loader Procedure
S 862-030
(1) Supply electrical power (AMM 24-22-00/201).
(a) Make sure that the power is not removed while you install software.
NOTE: A power interruption will cause a failure of the
____
software installation.
S 862-031
(2)
Make sure that the system select switch on the data loader control panel (P21, P23 or P37) is set to the NORM position.
S 862-032
(3)
Open this circuit breaker:
(a) On the circuit breaker panel, P18:
1) AIRBORNE DATA LOADER
(4)
To open the ADL front cover, pull at the top edge.
S 862-034
(5)
Push the eject button on the ADL.
S 012-033
(a) If a plastic protective disk is ejected from the disk drive, then remove it.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-15-11
ALL ú ú 01 Page 214 ú Mar 12/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(6) S 862-035Close this circuit breaker: (a) On the P18 panel: 1) AIRBORNE DATA LOADER
(7) S 862-036Wait until UNIT READY shows in the display.