(h)
(i)
A
737-300/400/500MAINTENANCE MANUAL
Swage the necessary flareless sleeves to the repair tube as told in the applicable section:
-
Swage BACS13BX Flareless Sleeves with the
Harrison Elastomer Swagers 5175, 5570, and 5720.
-
Swage BACS13BX Flareless Sleeves with the 6633K01
Harrison Roller Swaging Kit.
-Preset BACS13AP Flareless Sleeves.
-Remove the CRYOLIVE sleeve/coupling nut protective cap assembly from the liquid nitrogen and slide the assembly on to the tube, allowing it to warm to room temperature.
Assemble and tighten the flareless fittings which are part of
the repair section (AMM 20-10-09/401, Removal/Installation).
Measure all of the tube assembly length (L1) (see Fig. 806 and
809).
To find the necessary cutout length (L2) as shown on Fig. 806
and 809, use the procedure given in Fig. 810.
Remove the pressure from the systems where you will do the
repairs.
Cut out the damaged tube (L2). Trim the tube ends as shown in
Fig. 804.
When you make the installation, refer to the applicable section
as follows:
1) To use the Harrison elastomer swager to install BACS13BX flareless sleeves, refer to "Swage the BACS13BX flareless sleeves with the Harrison elastomer swagers 5175, 5570 and 5720".
2) To use the 6633K01 Harrison roller swaging kit to install BACS13BX flareless sleeves, refer to "Swage the BACS13BX Flareless Sleeves with the 6633K01 Harrison Roller Swaging Kit."
3) To use the Harrison 6777 Roller Swage Machine to install 35211 sleeves and 35212 unions, refer to "Swage Harrison 35211 sleeves and 35212 unions with the Harrison 6777 Roller Swage Machine."
4) To install BACS13AP flareless sleeves, refer to "Preset the BACS13AP Flareless Sleeves".
5) If you use H-couplings (BACC42W) for repair, refer to "Install the BACC42W H-coupling".
6) If you use Cryofit unions (3P02111) or 3PHS111 for repair, refer to "Install the 3P02111 and 3PHS111 Cryofit Couplings".
7) If you use Permaswage unions (D10283) for repair, refer to "Install the Permaswage Fittings".
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-10-51
ALL ú ú 01 Page 810 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
8) To install Cryolive flareless sleeve assembly, refer to "Install the Cryolive Flareless Sleeve Assemblies".
NOTE: Use only the complete Cryolive flareless sleeve
____ assembly, consisting of a Cryolive sleeve, coupling nut and plastic cap. The Cryolive flareless sleeve assembly, in Sizes 10, 12 and 16, requires use of a longer length coupling nut. The longer length coupling nuts are not interchangeable with standard BACN10- and MS21921 coupling nuts.
9) If you use Rynglok tube to tube unions for repair, refer to "The Rynglok Union Installation".
(j)
Install the repair section and tighten the nuts (AMM 20-50-11/201).
(k)
When you use a Cryofit Union or H-Coupling in the repair section, install it after you tighten the flareless fittings in their positions.
(l)
When you use a Permaswage union in the repair section, you must make allowance for swage growth. Tighten the repair section in position after installation of the Permaswage union.
(m)
When you replace a tube bend section, make sure you keep the minimum straight length specifications for all fittings (Fig. 812).
(n)
When you use a CRYOLIVE flareless sleeve/coupling nut in conjunction with a permanent Cryofit, H-Coupling or Permaswage union, tighten the flareless coupling nut hand tight before installing the permanent fitting to minimize axial preload on the CRYOLIVE sleeve.
TASK 20-10-51-308-137
3. Swage the BACS13BX Flareless Sleeves with the Harrison Elastomer Swagers________________________________________________________________________ 5175, 5570 and 5720 (Fig. 813)___________________
A. Equipment
(1)
Harrison Portable Swagers - 5175 and 5720
Harrison Stationary Swager - 5570
(Sierracin-Harrison - 3020 Empire Ave. -Burbank, California 91504)
(2)
"Tiplar" bore gauge or "Mueller" bore gage or
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 STANDARD PRACTICES(43)