20-10-51
ALL ú ú 03 Page 838 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(7) S 238-272Penterant check welded area (CMM 20-20-02).
(8) S 118-273Rinse with solvent, series 88 (AMM 20-30-88/201).
(9) S 798-267Hydrostatically test repaired tube to 240 psig per BAC5001-2. shall be no leakage. There
S 378-268
(10)
Finish repaired area with appropriate protective coatings as required to meet original tube finish requirements.
S 438-269
(11)
Install the repaired fuel tube per applicable maintenance manual procedure.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-10-51
ALL ú ú 03 Page 839 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
WRINKLE MEASUREMENTS
Permitted Ovality and Wrinkle of Hydraulic and Fire Extinguishing Tube Bends
Figure 801 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-10-51
ALL ú ú 03 Page 840 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L08037
A 737-300/400/500MAINTENANCE MANUAL
SYSTEM OPERATING PRESSURE TUBE OD TUBE MATERIAL (Inches) HEIGHT ALLOWABLE WRINKLE 1 Specified OD)* (Percent of ALLOWABLE OVALITY
Liquid: 1000 PSI To 3000 PSI (Including Return Lines) All Sizes Steel Stainless 0.010 5
Aluminum 0.010 5
Titanium 3AL-2.5V None Visible 3
Pneumatic And Oxygen: 160F or Temperature Above 1500 PSI Pressure Above All Sizes Steel Stainless 0.010 5
Pneumatic and Oxygen Temperature Less 1500 PSI Pressure Less Than Than 160F or 1000 PSI Pressure Less Than Systems: Other Liquid Systems: Less Than 1.0 Stainless Steel 0.040 10
Aluminum Alloy & Copper 0.020 10
1.0 Or Over, Less Than 2.0 Stainless Steel 0.060 10
Alloy & Copper Aluminum 0.030 10
2.0 Or Over, Less Than 3.0 Stainless Steel 0.080 5
Alloy & Copper Aluminum 0.040 5
3.0 Or Over Stainless Steel 0.100 5
Alloy & Copper Aluminum 0.050 5
* Specified Diameter = Drawing Specified Tube Diameter
OD MAX - OD MIN
1 PERCENT (OVALITY) = X 100
OD SPECIFIED*
____ OD MEASURED IN SAME PLANE.)
(NOTE:
NOTE: FOR ADDITIONAL INFORMATION ON TUBE BENDING, SEE SAE AIR 5378 "AIRCRAFT TYBE BENDING METHODS, TECHNIQUES AND TOOLING".
Permitted Ovality and Wrinkle of Hydraulic and Fire Extinguishing Tube Bends
Figure 801 (Sheet 2)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-10-51
ALL ú ú 03 Page 841 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L08092
A 737-300/400/500MAINTENANCE MANUAL
REPAIR METHOD - RECONNECTABLE WITH FLARELESS FITTING SLEEVES
TABLE A
Tube Material and Fitting Selection Tables
Figure 802 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
20-10-51
ALL ú ú 03 Page 842 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L08189
A 737-300/400/500MAINTENANCE MANUAL
* SEE TABLE D FOR ASSOCIATED APPROVED FITTINGS.
REPAIR METHOD - RECONNECTABLE WITH FLARELESS FITTING SLEEVES TABLE A
Tube Material and Fitting Selection Tables
Figure 802 (Sheet 2)