- push the line key adjacent to the TROUBLE SHOOTING DATA indication
- push the line key adjacent to the FG 1 COM indication, then FG 1 MON indication:
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 233
May 01/03R CES
. make sure that there is a snapshot related to an event 1 at AFS TEST time.
- on word 5, make sure that the fourth number is equal to: . 8 or 9 or A or B or C or D or E or F (on the command and monitoring channels).
(1) If the fourth number is not equal to the above values on the command channel:
- do a check of the wiring of the AP OWN ENGD COM OPP discrete from the FMGC 1 (1CA1) (from pin AA/14B to pin AB/3G)
- do a check of the wiring of the AP OWN ENGD COM OWN discrete from the FMGC 1 (1CA1) (from pin AB/10D to pin AB/3E) (Ref. ASM 22-85/03).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- replace the FCU (2CA) (Ref. AMM TASK 22-81-12-000-001) and (Ref. AMM TASK 22-81-12-400-001).
1 If the fault continues:
_
- do a check and repair the wiring of the CMD 1 SW COM discrete from the FCU (2CA) to the FMGC 1 (1CA1) (Ref. ASM 22-85/03).
(2) If the fourth number is not equal to the above values on the monitor channel:
- do a check of the wiring of the AP OWN ENGD MON OPP discrete from the FMGC 1 (1CA1) (from pin AD/14D to pin AE/3G)
- do a check of the wiring of the AP OWN ENGD MON OWN discrete from the FMGC 1 (1CA1) (from pin AE/12G to pin AE/3E) (Ref. ASM 22-85/03).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- replace the FCU (2CA) (Ref. AMM TASK 22-81-12-000-001) and (Ref. AMM TASK 22-81-12-400-001).
1 If the fault continues:
_
- do a check and repair the wiring of the CMD 1 SW MON discrete from the FCU (2CA) to the FMGC 1 (1CA1) (Ref. ASM 22-85/03).
C. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 234
May 01/03R CES
AP 2 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
_______________
- wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 2 (1CA2) to the relay (47CE1))
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-96-00-710-001 Operational Test of the AFS ASM 22-85/03
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC2/TAKE OV CKT:
- do a check and repair the wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 2 (1CA2) to the relay (47CE1)) (Ref. ASM 22-85/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 235
May 01/03R
CES Loss of the AP Pushbutton Switch Function on the FMGC 1
1. Possible Causes
_______________
- FMGC 1
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-96-00-710-001 Operational Test of the AFS
AMM 22-97-00-710-001 Operational Test of the LAND CAT III Capability