3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC1/C-M ARINC LINK:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check of the wiring of the FMGC OWN A (MON) bus from the FMGC1 (1CA1) to the first terminal block (Ref. ASM 22-86/02).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- do a check and repair the wiring of the FMGC MON OUT (MON) bus on the FMGC 1 (1CA1), pin AE/14A, 14B to pin AB/9J, 9K (Ref. ASM 22-86/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 205
Feb 01/98 CES Loss of the FMGC 2 Bus Feedback
1. Possible Causes
_______________
- FMGC-2 (1CA2)
- wiring of the FMGC OWN A (MON) bus from the FMGC 2 (1CA2) to the first terminal block
- wiring of the FMGC MON OUT (MON) bus on the FMGC 2 (1CA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-86/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC2/C-M ARINC LINK:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check of the wiring of the FMGC OWN A (MON) bus from the FMGC2 (1CA2) to the first terminal block (Ref. ASM 22-86/02).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- do a check and repair the wiring of the FMGC MON OUT (MON) bus on the FMGC 2 (1CA2), pin AE/14A, 14B to pin AB/9J, 9K (Ref. ASM 22-86/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 206
Feb 01/98 CES FMGC 1 Inoperative
1. Possible Causes
_______________
- FMGC-1 (1CA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2) AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2) AMM 22-91-00-710-001 Ground Scanning of the AFS
3. Fault Confirmation
__________________
A. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC1 (ALPHA FLOOR):
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
FMGC 1 Inoperative
1. Possible Causes
_______________
- FMGC-1 (1CA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------