- wiring of the AP OPP ENGD MON OPP and AP OPP ENGD COM OPP discretes from the FMGC 1 (1CA1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-85/03
3. Fault Confirmation
__________________
A. Test
(1) On the FCU, push the AP 2 pushbutton switch.
(2) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC1/AP2 ENGD WIRG:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the AP OPP ENGD MON OPP and AP OPP ENGD COM OPP discretes from the FMGC 1 (1CA1) to the first terminal block (Ref. ASM 22-85/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 231
May 01/03R CES
Loss of the Reception of the AP 1 ENGD Discrete Signal by the FMGC 2
1. Possible Causes
_______________
- FMGC-2 (1CA2)
- wiring of the AP OPP ENGD MON OPP and AP OPP ENGD COM OPP discretes from the FMGC 2 (1CA2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-85/03
3. Fault Confirmation
__________________
A. Test
(1) On the FCU, push the AP 1 pushbutton switch.
(2) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 2.
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FMGC2/AP1 ENGD WIRG:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the AP OPP ENGD MON OPP and AP OPP ENGD COM OPP discretes from the FMGC 2 (1CA2) to the first terminal block (Ref. ASM 22-85/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 232
May 01/03R CES
AP 1 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
_______________
- FCU (2CA)
- wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 1 (1CA1) to the relay (47CE1))
- wiring of the AP OWN ENGD COM OPP discrete from the FMGC 1 (1CA1)
- wiring of the AP OWN ENGD COM OWN discrete from the FMGC 1 (1CA1)
- wiring of the CMD 1 SW COM discrete from the FCU (2CA) to the FMGC 1 (1CA1)
- wiring of the AP OWN ENGD MON OPP discrete from the FMGC 1 (1CA1)
- wiring of the AP OWN ENGD MON OWN discrete from the FMGC 1 (1CA1)
- wiring of the CMD 1 SW MON discrete from the FCU (2CA) to the FMGC 1 (1CA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-81-12-000-001 Removal of the FCU (2CA)
AMM 22-81-12-400-001 Installation of the FCU (2CA)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-85/03
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1.
4. Fault Isolation
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行1(68)