B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AUTO FLT/FAC1/28VDC 5CC1 B04 49VU AUTO FLT/FAC1/26VAC 14CC1 B03
C. Test
(1) Open the circuit breaker 5CC1.
(2) After a minimum of 10 seconds, close the circuit breaker 5CC1.
(3) After 2 minutes, do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 1.
4. Fault Isolation
_______________
R
A. If the test gives the maintenance message AFS: FAC1/YD ACTR1 3CC1: R R - open the circuit breakers 5CC1 and 14CC1, R - remove the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and disconnect R the plug at the YAW DAMPER Servo-Actuator 1, R - do a check of the wiring between respectively:
R . the pins AF/4 and AF/6 of the FAC1 and the pins A/E and A/D of the
R solenoid valve of the YAW DAMPER Servo-Actuator 1,
R . the pins AC/4 and AC/6 of the FAC1 and the pins B/A and B/B of the
R solenoid valve 2 of the YAW DAMPER Servo-Actuator 1.
R (Ref. ASM 22-68/04)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-63-00∞∞∞∞∞∞∞∞∞∞Page 202
May 01/03 CES
R (1) If the wiring is not correct:
R - repair it.
R (2) If the wiring is correct:
R - connect the above mentioned plug,
R - do a check of the impedance between respectively:
R . the pin AC/4 and the pin AC/6,
R . then the pin AF/4 and the pin AF/6 of the FAC-1 rack connector.
R NOTE : The impedance must be more than 40 Ohms.
____
R (a) If the impedance is correct:
R - replace the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-400-002).
R (b) If the impedance is not correct:
R - replace the faulty solenoid valve 1 and/or 2 of the SERVO
R ACTR-YAW DAMPER, (3CC1) (Ref. AMM TASK 27-26-51-000-003) and
R (Ref. AMM TASK 27-26-51-400-003),
R - install the above removed FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-
400-002), R - close the circuit breakers 5CC1 and 14CC1. R
R B. If the test does not give the maintenance message AFS: FAC1/YD ACTR1
R 3CC1:
R - do the operational test of the yaw damper function (Ref. AMM TASK 22-R 63-00-710-001).
R
R (1) If the yaw damper function is not correct:
R - replace the FAC-1 (1CC1), (Ref. AMM TASK 22-66-34-000-002) and
R (Ref. AMM TASK 22-66-34-400-002).
R (2) If the fault continues:
R - do a check and repair the wiring of the solenoid valve 1 and 2 of
R the SERVO ACTR-YAW DAMPER, 1 (3CC1), (Ref. ASM 22-68/04),
R - if the wiring is correct, replace the solenoid valve 1 and/or 2 of
R the SERVO ACTR-YAW DAMPER, (3CC1), (Ref. AMM TASK 27-26-51-000-003)
R and (Ref. AMM TASK 27-26-51-400-003).
R (3) If the fault continues:
R - do a check and repair the wiring of the pressure switch of the
R SERVO ACTR-YAW DAMPER, 1 (3CC1) (Ref. ASM 22-68/04),
R - if the wiring is correct, replace the pressure switch of the SERVO
R ACTR-YAW DAMPER, (3CC1), (Ref. AMM TASK 27-26-51-000-004) and (Ref.
AMM TASK 27-26-51-400-004).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-63-00∞∞∞∞∞∞∞∞∞∞Page 203
May 01/03 CES
R (4) If the fault continues:
- do a check and repair the wiring of the YAW V1 COM and YAW V2 COM
discretes (from the yaw damper servo-actuator,1 (3CC1) to the FAC 1
(1CC1)) (Ref. ASM 22-68/04).
R - if the wiring is correct,do a check and repair the wiring of the
R servovalve SERVO ACTR-YAW DAMPER, 1 (3CC1) (Ref. ASM 22-68/04),
R - if the wiring is correct, replace the servovalve of the SERVO
R ACTR-YAW DAMPER, 2 (3CC1), (Ref. AMM TASK 27-26-51-000-002) and
R (Ref. AMM TASK 27-26-51-400-002),
R
R - if the fault persists, replace the SERVO ACTR-YAW DAMPER, 1
R (3CC1), (Ref. AMM TASK 27-26-51-000-001) and (Ref. AMM TASK 27-26-
51-400-001).
R C. Do the test given in Para. 3.C.
Loss of the Yaw Damper Function on the FAC 2
1. Possible Causes
_______________
- FAC-2 (1CC2)
- SERVO ACTR-YAW DAMPER, 2 (3CC2)
- wiring
- solenoid valve 1 or 2 of the SERVO ACTR-YAW DAMPER, 2 (3CC2) R - solenoid valve 1 and/or 2 of the SERVO ACTR-YAW DAMPER, 2 (3CC2)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行1(106)