• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:19来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1) On the FCU, push the AP2 pushbutton switch.

 (2) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).


 4. Fault Isolation
_______________
 A. If the test gives the maintenance messages:
 AFS: FMGC2/AP ENGD FDBK
 AFS: FMGC1/AP2 ENGD WIRG
 AFS: FAC1/AP2 ENGD WIRING

 - remove the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001)

 - do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).


 (1) If the test gives the message: AFS TEST OK

 - replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-400-001).

 (2) If the test result of the FMGC2 gives the maintenance message AFS: FMGC2/AP ENGD FDBK:


 - replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 217
 May 01/03R CES


 (3) If the fault continues:

 - replace FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) (Ref. AMM TASK 22-66-34-400-002).

 (4) If the fault continues:


 - do a check and repair the wiring of the AP OWN ENGD (COM and MON) OPP and AP OPP ENGD (COM and MON) OPP discretes (Ref. ASM 22-85/03).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 218
 May 01/03R
 CES  Disagree between the AP ENGD Discretes (FMGC1 and FMGC2)


 1. Possible Causes
_______________
 - FMGC-2 (1CA2)

 - FMGC-1 (1CA1)

 - FAC-2 (1CC2)

 - wiring of the AP OWN ENGD (COM and MON) OPP and AP OPP ENGD (COM and MON) OPP discretes


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
 AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
 AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
 AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
 AMM 22-96-00-710-001 Operational Test of the AFS
 ASM 22-85/03

 3. Fault Confirmation
__________________
 A. Test
 (1) On the FCU, push the AP1 pushbutton switch.

 (2) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).


 4. Fault Isolation
_______________
 A. If the test gives the maintenance messages:
 AFS: FMGC1/AP ENGD FDBK
 AFS: FMGC2/AP1 ENGD WIRG
 AFS: FAC2/AP1 ENGD WIRING:

 - remove the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001)

 - do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).


 (1) If the test gives the message: AFS TEST OK

 - replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-400-001).

 (2) If the test result of the FMGC1 gives the maintenance message AFS: FMGC1/AP ENGD FDBK:


 - replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) (Ref. AMM TASK 22-83-34-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 219
 May 01/03R CES


 (3) If the fault continues:

 - replace the FAC-2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) (Ref. AMM TASK 22-66-34-400-002).

 (4) If the fault continues:


 - do a check and repair the wiring of the AP OWN ENGD (COM and MON) OPP and AP OPP ENGD (COM and MON) OPP discretes (Ref. ASM 22-85/03).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-11-00∞∞∞∞∞∞∞∞∞∞Page 220
 May 01/03R
 CES  Loss of the AP1 ENGD Feedback Discretes


 1. Possible Causes
_______________
 - FMGC-1 (1CA1)

 - wiring of the AP OWN ENGD MON OWN discrete (from the FMGC 1 (1CA1) pin AE/3E to the first terminal block)

 - wiring of the AP OWN ENGD COM OWN discrete (from the FMGC 1 (1CA1) pin AB/3E to the first terminal block)

 - wiring of the AP OWN ENGD MON OPP discrete (from the FMGC 1 (1CA1) pin AE/3G to the first terminal block)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行1(64)