CODE DESIGNATION LGCIU CONTROL TSM CFDS No.1 No.2 FAULT PROCEDURE MESSAGE IN 32-31-00 NUMBER ------------------------------------------------------------------------------switch disagreement 156 Nose gear LH door open proximity 1 2 no 854 50 switch disagreement 157 RH gear door closed proximity 1 2 no 854 51 switch disagreement 158 LH gear door closed proximity 1 2 no 854 52 switch disagreement 159 Nose gear door closed proximity 1 2 no 854 53
switch disagreement
160 )
thru ) Not used
165 )
NOTE: The specified proximity switches identify total sensing circuits (a proximity sensor and a channel of a proximity conditioning card).
-------------------------------------------------------------------------------
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞32-31-00∞∞∞∞∞∞∞∞∞∞Page 309
Nov 01/00R
CES
------------------------------------------------------------------------------
R CODE DESIGNATION LGCIU CONTROL TSM CFDS
R No.1 No.2 FAULT PROCEDURE MESSAGE IN 32-31-00 NUMBER ------------------------------------------------------------------------------166 Nose L/G extended/centered 1 2 Yes 815 17 signal conditioning failure 167 RH L/G extended signal 1 2 Yes 813 15 conditioning failure 168 Nose L/G uplock signal 1 2 Yes 827 30 conditioning failure 169 RH L/G uplock signal 1 2 Yes 825 28 conditioning failure 170 RH L/G door fully open signal 1 2 Yes 817 18 conditioning failure 171 Nose L/G downlock signal 1 2 Yes 824 27 conditioning failure 172 Nose L/G RH door fully open 1 2 Yes 818 20 signal conditioning failure 173 Nose L/G LH door fully open 1 2 Yes 818 21 signal conditioning failure 174 LH L/G downlock signal 1 2 Yes 823 26 conditioning failure 175 RH L/G downlock signal 1 2 Yes 822 25 conditioning failure 176 Nose L/G doors closed signal 1 2 Yes 821 24 conditioning failure 177 RH L/G doors closed signal 1 2 Yes 819 22 conditioning failure 178 Proximity card 1 bus error 1 2 Yes 802 1 179 Not used 180 Not used 181 LH L/G uplock signal 1 2 Yes 826 29 conditioning failure 182 LH L/G extended signal 1 2 Yes 814 16 conditioning failure 183 FWD cargo door safety mechanism 1 No 832 33 signal conditioning failure 184 AFT cargo door safety mechanism 1 No 833 34 signal conditioning failure 185 FWD cargo door lockshaft signal 2 No 834 35 conditioning failure 186 AFT cargo door lockshaft signal 2 No 835 36 conditioning failure 187 LH L/G door closed signal 1 2 Yes 820 23 conditioning failure 188 LH L/G door fully open signal 1 2 Yes 817 19 conditioning failure 189 FWD cargo door locking handle 1 No 830 31 signal conditioning failure 190 AFT cargo door locking handle 1 No 831 32
------------------------------------------------------------------------------CODE DESIGNATION LGCIU ON TSM CFDS No.1 No.2 STANDBY PROCEDURE MESSAGE IN 32-31-00 NUMBER ------------------------------------------------------------------------------signal conditioning failure 191 LH flap disconnect signal 1 2 No 828 37 conditioning failure 192 RH flap disconnect signal 1 2 No 829 38
conditioning failure 193 Not used 194 Not used 195 Not used 196 Not used 197 Proximity card 2 bus error 1 2 Yes 802 1 198 LH & RH L/G compressed interface 1 2 No 802 1
signal 1 disagrees with BITE
proximity settings
199 LH & RH L/G compressed interface 1 2 No 802 1 signal 2 disagrees with BITE proximity settings
200 LH & RH L/G compressed interface 1 2 No 802 1 signal 3 disagrees with BITE proximity settings
201 LH & RH L/G compressed interface 1 2 No 802 1 signal 4 disagrees with BITE proximity settings
202 Nose L/G compressed interface 1 2 No 802 1 signal 1 disagrees with BITE proximity settings
203 LH L/G compressed interface 1 2 No 802 1 signal 1 disagrees with BITE proximity settings
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 起落架 LANDING GEAR 1(81)