R CODE DESIGNATION LGCIU CONTROL TSM CFDS
R No.1 No.2 FAULT PROCEDURE MESSAGE IN 32-31-00 NUMBER ------------------------------------------------------------------------------046 Not used 047 Not used 048 L/G retract solenoid energized 1 2 Yes 806 1 when neutral selected 049 L/G extend solenoid energized 1 2 Yes 806 1 when neutral selected 050 L/G doors open solenoid 1 2 Yes 807 1 energized when neutral selected 051 L/G doors close solenoid 1 2 Yes 807 1 energized when neutral selected 052 L/G retract solenoid LGCIU 1 2 Yes 806 1 transistors incompatible 053 L/G extend solenoid LGCIU 1 2 Yes 806 1 transistors incompatible 054 L/G doors open solenoid LGCIU 1 2 Yes 807 1 transistors incompatible 055 L/G doors close solenoid 1 2 Yes 807 1 LGCIU transistors incompatible 056 Any solenoid energized when 1 2 Yes 806/807 1 driver output(s) disabled 057 Output card power supply failure 1 2 Yes 802 1 058 Nose L/G extended/centered 1 2 Yes 802 1 normal output = complementary
------------------------------------------------------------------------------CODE DESIGNATION LGCIU ON TSM CFDS No.1 No.2 STANDBY PROCEDURE MESSAGE IN 32-31-00 NUMBER ------------------------------------------------------------------------------output 059 RH L/G extended normal output = 1 2 Yes 802 1 complementary output 060 Nose L/G uplock normal output = 1 2 Yes 802 1 complementary output 061 RH L/G uplock normal output = 1 2 Yes 802 1 complementary output 062 RH L/G door fully open normal 1 2 Yes 802 1 output = complementary output 063 Nose L/G downlock normal 1 2 Yes 802 1 output = complementary output 064 Nose L/G RH door open normal 1 2 Yes 802 1 output = complementary output 065 Nose L/G LH door open normal 1 2 Yes 802 1 output = complementary output 066 LH L/G downlock normal output 1 2 Yes 802 1 = complementary output 067 RH L/G downlock normal output 1 2 Yes 802 1 = complementary output 068 Nose L/G doors uplock normal 1 2 Yes 802 1 output = complementary output 069 RH L/G door uplock normal 1 2 Yes 802 1 output = complementary output 070 Proximity card 1 bus error wrong 1 2 Yes 802 1 bit pattern 071 Proximity card 1 power supply 1 2 Yes 802 1
failure
072 Not used
073 Not used
074 LH L/G uplock normal output = 1 2 Yes 802 1 complementary output
075 LH L/G extended normal output 1 2 Yes 802 1 = complementary output
076 FWD cargo door safety mechanism 1 No 802 1 normal output = complementary output
077 AFT cargo door safety mechanism 1 No 802 1 normal output = complementary output
078 FWD cargo door lockshaft normal 2 No 802 1 output = complementary output
079 AFT cargo door lockshaft normal 2 No 802 1 output = complementary output
080 LH L/G door locked up normal 1 2 Yes 802 1 output = complementary output
081 LH L/G door fully open normal 1 2 Yes 802 1 output = complementary output
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞32-31-00∞∞∞∞∞∞∞∞∞∞Page 305
Aug 01/00R
CES
------------------------------------------------------------------------------CODE DESIGNATION LGCIU ON TSM CFDS No.1 No.2 STANDBY PROCEDURE MESSAGE IN 32-31-00 NUMBER
------------------------------------------------------------------------------
082 Not used
083 Not used
084 )
thru ) Not used
089 )
090 Proximity card 2 bus error wrong 1 2 Yes 802 1 bit pattern
091 Proximity card 2 power supply 1 2 Yes 802 1 failure
092 LH & RH L/G compressed interface 1 2 No 802 1 signal 1 incorrect
093 LH & RH L/G compressed interface 1 2 No 802 1 signal 2 incorrect
094 LH & RH L/G compressed interface 1 2 No 802 1 signal 3 incorrect
095 LH & RH L/G compressed interface 1 2 No 802 1 signal 4 incorrect
096 Nose L/G compressed interface 1 2 No 802 1 signal 1 incorrect