-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------On the MCDU MENU page:
-the ATSU prompt comes into view.
NOTE : If the ATSU Router is not
____ initialized, the ACARS STBY memo or DATALINK ATSU FAULT + ATSU INIT FAULT warning comes into view on the upper ECAM DU.
R **ON A/C 106-149, 151-156, 159-199, 201-299, 301-399, 401-499,
Post SB 46-1013 For A/C 151-156,201-209,
Subtask 46-21-00-970-053-A
A. Uploading of the ATSU Software Disks
CAUTION : DURING THE UPLOADING OF THE AOC SOFTWARE/DATABASE AND ATSU
_______ CONFIGURATION/ROUTER PARAMETERS SOFTWARE INTO THE ATSU (FIN'S 22TX, 24TX, 21TX, 30TX), MAKE SURE THAT:
-
MAINTENANCE PERSONNEL DO NOT CHANGE THE SOURCE OF THE AIRCRAFT POWER SUPPLY (GROUND POWER UNIT, APU, ...)
-
MAINTENANCE PERSONNEL DO NOT TOUCH OR MOVE THE DATA LOADER SELECTOR(S)/DLRB AND THE MDDU/PDL. IF YOU DO NOT OBEY THESE TWO PRECAUTIONS, THERE WILL BE ERASURE OF ALL THE AOC SOFTWARE/DATABASE AND ATSU CONFIGURATION/ ROUTER PARAMETERS SOFTWARE LOADED INTO THE ATSU. IT WILL THEN BE NECESSARY TO START THE UPLOADING PROCEDURE OF ALL THE AOC SOFTWARE/DATABASE AND ATSU CONFIGURATION/ROUTER PARAMETERS SOFTWARE AGAIN.
Upload
-first, the ATSU A/C INTERFACE software disk (20TX)
-then, the ATSU CONFIGURATION software disk (21TX) and/or ATSU ROUTER PARAMETERS software disk (30TX).
NOTE : You can upload these last two software disks independently if the
____
ATSU A/C INTERFACE software is uploaded.
NOTE : The loading time for a full disk is twelve minutes approximately.
____
NOTE : On the Data Loading Selector, set the ON/OFF switch to OFF between
____ each software uploading procedure. Thus, the ATSU performs a Power
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 46-21-00Page 314 1401-499, 1Aug 01/05 1 1 1CES 1 On Self-Test (POST) to validate each uploading and the software is operational.
NOTE : After the uploading procedures, the operator must do a check of
____ the reference of the data loaded in the computer, on the MCDU.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the overhead panel, on the Data Loading Selector:
-set the ON/OFF switch to ON.
2. On the overhead panel, on the Data Loading Selector:
-push the PREV or NEXT key until you get the ATSU indication.
3. On the overhead panel, on the Data Loading Selector:
-push the SEL CTL key.
4. On the MDDU:
-put the disk into the disk drive, the label in the forward direction.
On the display of the Data LoadingSelector:
-DB/N: PUSH NEXT/PREV indication is shown.
On the Multipurpose Disk Drive Unit (MDDU):
-the < < MDDU READY > > indication is shown.
On the display of the Data LoadingSelector:
-ATSUNOT SELECTED indication is shown.
On the display of the Data LoadingSelector:
-ATSU SELECTED indication is shown.
On the MDDU:
-the READY indication is shown
On the MDDU:
-then, the WAIT RESPONSE indication isshown.
On the MDDU:
-the TRANS IN PROG indication is shown.
R 1EFF : 106-149, 151-156, 159-199, 201-299, 1 46-21-00Page 315 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
NOTE : If a transfer fault occurs, we____ recommend that you wait a minimum of three minutes:
- after you set the ON/OFF switch on the Data Loading Selector to OFF and
- before you start the uploading of the ATSU software again. Thus, the ATSU can complete its Power On Self-Test.
NOTE : If more than one disk is____
necessary for uploading, the EJECT DISK and INSERT DISK
indications are shown one after
the other. They tell the operator to put a new disk into the MDDU.
On the upper ECAM DU: - the COM ACARS FAULT or DATALINK ATSU
FAULT warning is shown.
On the MCDU:
- the ATSU prompt is not shown. - when all the disks are loaded in the
computer, the TRANSF COMPLETE indication is shown.
5. On the overhead panel, on the Data Loading Selector: - push the SEL CTL key. On the display of the Data LoadingSelector:- ATSU NOT SELECTED
indication is shown.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 信息系统 INFORMATION SYSTEMS(39)