(e)
 Remove the actuator (1),(2).
 (f)
 Remove the sliding bush (4) from the flanged bush (6) in the lever (5).
 NOTE : Do not remove the flanged bushes (6),(7) from the levers
____ (5),(11). The bushes (6),(7) are safetied in the levers (5),(11) with loctite.
 1EFF : ALL 1 27-26-51Page 406 1 1 Aug 01/01R 1 1 1CES 1
 TASK 27-26-51-400-001
 Installation of the Yaw Damper Servo Actuator (3CC1) and (3CC2)
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:
 -
THE FLIGHT CONTROLS
 -
THE FLIGHT CONTROL SURFACES
 -
THE LANDING GEAR AND THE RELATED DOORS
 -COMPONENTS THAT MOVE.
 WARNING : PRESSURIZE ONLY THE HYDRAULIC SYSTEM(S) THAT IS (ARE) NECESSARY FOR
_______ THE TASK. ISOLATE THE OTHER HYDRAULIC SYSTEM(S) BEFORE YOU SUPPLY HYDRAULIC POWER TO THE AIRCRAFT.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific drainage container
 No specific warning notices
 No specific adjustable access platform 6.0 m (19 ft. 8 in.)
 No specific Torque Wrench : range 0.20 to 3.60 m.daN
 (2.00 to 26.00 lbf.ft)
 98D27207516000 1 RIGGING PIN SET R 98D27207549000 1 PIN - RIGGING