On the lower ECAM display unit, on the F/CTL page:
-
the pointer of the RUD indicator moves smoothly to the right mark.
The rudder moves smoothly to the right.
On the lower ECAM display unit, on theF/CTL page:
-the pointer of the RUD indicatormoves smoothly from the right mark to the left mark.
The rudder moves smoothly from the right to the left.
On the lower ECAM display unit, on theF/CTL page:
-the pointer of the RUD indicator moves smoothly to the neutral position.
The rudder moves smoothly to the neutral position.
On the maintenance panel 50VU:
-
the OFF legend of the HYD/LEAK MEASUREMENT VALVES/G pushbutton switch goes off,
-
the OFF legend of the HYD/LEAK
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R switch.
R R R R 6. On the CAPT or F/O side: - slowly push the right rudder pedal until it touches the mechanical stop.
R
R R R R R 7. Slowly release the right rudder pedal and push the left pedal until it touches the mechanical stop.
R R
R R R R R 8. Slowly release the left rudder pedal.
R R R
R R R R R R R 9. On the maintenance panel 50VU: - push the HYD/LEAK MEASUREMENT VALVES/Y pushbutton switch. - release the HYD/LEAK MEASUREMENT VALVES/G pushbutton switch.
R R R 10. On the CAPT or F/O side: - slowly push the right rudder pedal until it touches the mechanical stop.
MEASUREMENT VALVES/B pushbutton
switch comes on.
On the lower ECAM display unit, on the F/CTL page:
-the pointer of the RUD indicator moves smoothly to the right mark.
The rudder moves smoothly to the right.
On the lower ECAM display unit, on the F/CTL page:
-the pointer of the RUD indicator moves smoothly from the right mark to the left mark.
The rudder moves smoothly from the right to the left.
On the lower ECAM display unit, on the F/CTL page:
-the pointer of the RUD indicator moves smoothly to the neutral position.
The rudder moves smoothly to the neutral position.
On the maintenance panel 50VU:
-
the OFF legend of the HYD/LEAK MEASUREMENT VALVES/Y pushbutton switch goes off,
-
the OFF legend of the HYD/LEAK MEASUREMENT VALVES/G pushbutton switch comes on.
On the lower ECAM display unit, on the F/CTL page:
-
the pointer of the RUD indicator moves smoothly to the right mark.
The rudder moves smoothly to the right.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
11. Slowly release the right rudder pedal and then push the left rudder pedal until it touches the mechanical stop. On the lower ECAM display unit, on theF/CTL page:- the pointer of the RUD indicatormoves smoothly from the right mark to the left mark.
The rudder moves smoothly from the right to the left.
12. Slowly release the left rudder pedal. On the lower ECAM display unit, on theF/CTL page : - the pointer of the RUD indicator moves smoothly to the neutral position.
R The rudder moves smoothly to the neutral position.
5. Close-up________
Subtask 27-24-00-860-058
A. Put the aircraft back to its initial configuration.
R R R R (1) On the maintenance panel 50VU: - push the HYD/LEAK MEASUREMENT VALVES/G and HYD/LEAK MEASUREMENT VALVES/B pushbutton switches (on these pushbutton switches, the OFF legends go off).
R R (2) Depressurize the hydraulic systems (Ref. TASK 29-10-00-864-003) (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001).
R (3) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
R (4) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
TASK 27-24-00-820-001
Adjustment of the Rudder Neutral Position
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.