the RUD/G, B, Y symbols are green,
 -
the pointer of the RUD indicator moves to the neutral position.
 A. Put the aircraft back to its initial configuration.
 (1)
 Depressurize the aircraft hydraulic systems (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001) (Ref. TASK 29-10-00-864-003).
 (2)
 Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
 (3)
 De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
 (4)
 Make sure that the work area is clean and clear of tool(s) and other items.
 1EFF : ALL 1 27-24-00Page 503 1 1 May 01/00R 1 1 1CES 1
 TASK 27-24-00-710-002
 Operational Test of the Rudder Servocontrols with Individual Hydraulic System
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:
 -
THE FLIGHT CONTROLS
 -
THE FLIGHT CONTROL SURFACES
 -
THE LANDING GEAR AND THE RELATED DOORS
 -COMPONENTS THAT MOVE.
 WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
 CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 272400-01
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power R 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground R Power Supply
 29-10-00-864-003  Depressurize the Blue Hydraulic System
 29-23-00-863-001  Pressurize the Green Hydraulic System from the Yellow Hydraulic System through the PTU with the Electric Pump
 29-23-00-864-001 Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU 29-24-00-863-001 Pressurize the Yellow Hydraulic System with the
 Electric Pump
 29-24-00-864-001 Depressurize the Yellow Hydraulic System
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 3. Job Set-up__________ 
 Subtask 27-24-00-860-057 
 A. Aircraft Maintenance Configuration 
 (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).  
R R  (2) Pressurize the aircraft hydraulic systems (Ref. TASK 29-23-00-863-001) (Ref. TASK 29-24-00-863-001) (Ref. TASK 29-10-00-863-003).  
R  (3) On the center pedestal, on the panel 110VU, make sure that the RUD TRIM indicator shows O.  
R  (4) Do the EIS start procedure (Ref. TASK 31-60-00-860-001).  
R  (5) On the center pedestal, on the ECAM control panel, push the F/CTL key (on the lower ECAM display unit, the F/CTL page comes into view).  
R  (6) On the HYD section of the maintenance panel 50VU, make sure that: - the HYD/LEAK MEASUREMENT VALVES/B, HYD/LEAK MEASUREMENT VALVES/G, HYD/LEAK MEASUREMENT VALVES/Y pushbutton switches are pushed (the OFF legends of these pushbutton switches are off).  
R R R  (7) On the overhead panel 23VU, make sure that the FLT CTL/FAC1 pushbutton switch is pushed (on this pushbutton switch, the FAULT and OFF legends are off).  
R R R  (8) On the overhead panel 24VU, make sure that the FLT CTL/FAC2 pushbutton switch is pushed (on this pushbutton switch, the FAULT and OFF legends are off).
 4. Procedure
_________ Subtask 27-24-00-710-051 R A. Do this test: -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R
R 1. On the maintenance panel 50VU: 
R - release the HYD/LEAK 
R MEASUREMENT VALVES/G and 
R HYD/LEAK MEASUREMENT VALVES/Y 
R pushbutton switches.
R 2. On the CAPT or F/O side: 
R - slowly push the right rudder 
R pedal until it touches the 
R mechanical stop.
R 3. Slowly release the right rudder pedal and then push the left rudder pedal until it touches the mechanical stop. 
R 4. Slowly release the left rudder pedal. 
R 5. On the maintenance panel 50VU: R - push the HYD/LEAK MEASUREMENT R VALVES/G pushbutton switch. R - release the HYD/LEAK R MEASUREMENT VALVES/B pushbutton On the maintenance panel 50VU: 
 