• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:37来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1) Make sure that the ground service network is energized (Ref. TASK 24-42-00-861-001).
 Subtask 21-26-55-010-059
 B. Get Access
 (1) Make sure that the access platform is in position at the access door
 822.
 (2) Make sure that the access door 822 is opened. Subtask 21-26-55-865-054
 C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR COND/AVNCS VENT/CTL 6HQ D06
 Subtask 21-26-55-210-051
 D. Visual Inspection
 (1) Make sure that the clamps, the flexible sleeve and the valve are in good condition; replace if necessary.
 1EFF : ALL 1 21-26-55Page 415 1 1 May 01/05R 1 1 1CES 1


 4. Procedure
_________ (Ref. Fig. 402/TASK 21-26-55-991-003) R **ON A/C 001-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 21-26-55-420-052
 A. Installation of the Skin Exchanger Isolation Valve
 (1)
 Remove the blanking plugs from the disconnected line ends.

 (2)
 Install the flexible sleeve (26) on the duct (28).

 (3)
 Put the new O-ring (22) in the groove of the duct (20).

 (4)
 Install the valve (23) in the flexible sleeve (26). NOTE : The arrow that indicates the air flow points up.

____

 (5)
 Make sure that the valve (23) is in the correct angular position . The electrical cable must not be too tight or too loose.

 (6)
 Install the clamp (21) and tighten to the torque value which is indicated on the clamp.

 (7)
 Put the flexible sleeve (26) in position.

 (8)
 Install and tighten the clamps (25) and (27). NOTE : Use the clamps (25) and (27) kept during the removal

____
 procedure.


 (9)
 Remove the blanking caps from the electrical connectors.


 (10)
 Make sure that the electrical connectors are clean and in the correct condition.

 (11)
 Connect the electrical connector (24).

 


R  **ON A/C 051-052, 
R  Subtask 21-26-55-420-052-A 
R  A. Installation of the Skin Exchanger Isolation Valve 
R  (1) Remove the blanking plugs from the disconnected line ends. 
R  (2) Install the flexible sleeve (26) on the duct (28). 
R  (3) Put the new O-ring (22) in the groove of the duct (20). 
R  (4) Install the valve (23) in the flexible sleeve (26). 
R  NOTE : The arrow that indicates the air flow points up.____ 
R  (5) Make sure that the valve (23) is in the correct angular position . 
R  The electrical cable must not be too tight or too loose. 
R  (6) Install the clamp (21) and tighten to the torque value which is 
R  indicated on the clamp. 
R  (7) Put the flexible sleeve (26) in position. 
R  (8) Install and tighten the clamps (25) and (27). 
R  (9) Remove the blanking caps from the electrical connectors. 
R  (10) Make sure that the electrical connectors are clean and in the correct 
R  condition. 
R  (11) Connect the electrical connector (24). 
R  **ON A/C ALL
 Subtask 21-26-55-865-055
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s):
 6HQ.

 

 Subtask 21-26-55-710-051
 C. Do this Test
 (1) Do an operational test of the ventilation system of the avionics equipment (Ref. TASK 21-26-00-710-001).
 NOTE : As an alternative procedure, you can do this operational test
____ without the CFDS (Ref. TASK 21-26-00-710-001).
 5. Close-up
________ Subtask 21-26-55-410-052
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the access door 822.


 (3) Remove the access platform(s). Subtask 21-26-55-862-053
 B. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).

 1EFF : ALL 1 21-26-55Page 418 1 1 May 01/05R 1 1 1CES 1


 TASK 21-26-55-000-003
 Removal of the Avionics Ventilation Skin Exchanger Outlet Bypass Valve (23HQ)

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 2(95)