• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:37来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (2)
 Close the access door 824 (Ref. TASK 52-41-00-410-002).


 (3) Remove the access platform(s). Subtask 21-26-43-865-098
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1HQ, 2HQ, 3HQ, 5HQ, 6HQ
R 1EFF : 002-049, 051-099, 101-105, 1 21-26-43Page 308 1 1 Config-1 May 01/05 1 1 1CES 1 Subtask 21-26-43-861-095


 C. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 21-26-43-862-094
 D. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
R 1EFF : 002-049, 051-099, 101-105, 1 21-26-43Page 309 1 1 Config-1 May 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-105,

 

 TASK 21-26-43-600-002
 Servicing of the Filter Cartridge (2082HM)
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 212643-02
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific access platform 1.6 m (5 ft. 3 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
 the External Power 52-41-00-410-002 Close the Avionics Compartment Doors after Access CMM 212600 21-26-43-991-003 Fig. 302
 3. Job Set-up
__________
 Subtask 21-26-43-862-064
 A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
R 1EFF : 001-049, 051-099, 101-105, 1 21-26-43Page 310 1 1 Config-1 May 01/05 1 1 1CES 1 Subtask 21-26-43-861-064


 B. Energize the ground service network (Ref. TASK 24-42-00-861-001). Subtask 21-26-43-865-066
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR COND/AVNCS VENT/CTL 6HQ D06 49VU AIR COND/AVNCS VENT/CTL 5HQ D05 122VU AIR COND/AVNCS/VENT/MONG 3HQ Y17 123VU AVNCS VENT/BLOWER/FAN 1HQ AD10 123VU AVNCS VENT/EXTC/FAN 2HQ AE02
 Subtask 21-26-43-010-057
 D. Get Access
 (1)
 Put the access platform in position at the access door 824.

 (2)
 Open the access door 824.


 4. Procedure
_________ (Ref. Fig. 302/TASK 21-26-43-991-003) Subtask 21-26-43-020-057
 A. Remove the filter cartridge.
 (1)
 Release each of the four fasteners:

 (a)
 move the lock (14) towards the door of the body (10).

 (b)
 lift the fastener.

 

 (2)
 Push the door and lift the fasteners to fully release the door of the body (10).

 (3)
 Open the door of the body (10).

 (4)
 Hold the two ends of the ring (12) with the loop bowden cable.


R 1EFF : 001-049, 051-099, 101-105, 1 21-26-43Page 311 1 1 Config-1 May 01/05 1 1 1CES 1


 Filter
 Figure 302/TASK 21-26-43-991-003

R 1EFF : 001-049, 051-099, 101-105, 1 21-26-43Page 312 1 1 Config-1 May 01/05 1 1 1CES 1


 (5)
 Pull the filter (13) with the straps to disengage the bearing from its housing.

 (6)
 Remove the filter (13) from the body (10).


 (7)
 Bend the end of the ring (12) and remove it. Subtask 21-26-43-615-055

 B.
 Clean the filter cartridge (Ref. CMM 212600). Subtask 21-26-43-160-057

 C.
 Clean the component interface and/or the adjacent area (Ref. CMM 212600). Subtask 21-26-43-210-057

 D.
 Do an inspection of the component interface and/or the adjacent area. Subtask 21-26-43-420-057


 E. Install filter cartridge.
 (1)
 Move apart the two ends of the ring (12) to install it into the groove of the filter element (13).

 (2)
 Hold the two ends of the ring with the bowden cable.

 (3)
 Put the assembly through the door into the body (10) and engage the bearing of the filter (13) into the housing.
 
中国航空网 www.aero.cn