R Subtask 21-26-43-861-115
R C. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
R Subtask 21-26-43-862-110
R D. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
R TASK 21-26-43-600-019 R Servicing of the Filter Cartridge (2082HM) R 1. Reason for the Job
__________________ R Self Explanatory R 2. Job Set-up Information
______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------R REFERENCE QTY DESIGNATION R -------------------------------------------------------------------------------
R No specific circuit breaker(s) safety clip(s) R No specific access platform 1.6 m (5 ft. 3 in.)
R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 24-41-00-861-002 R R 24-41-00-862-002 R R 24-42-00-861-001 R R 24-42-00-862-001 R R 52-41-00-410-002 R CMM 212600 R 21-26-43-991-031
R 3. Job Set-up
__________
R Subtask 21-26-43-862-111 Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Energize the Ground Service Network from the External Power De-energize the Ground Service Network Supplied from the External Power Close the Avionics Compartment Doors after Access
Fig. 304
R A. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-R 002).
R Subtask 21-26-43-861-116
R B. Energize the ground service network (Ref. TASK 24-42-00-861-001).
R Subtask 21-26-43-865-119
R C. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 49VU AIR COND/AVNCS VENT/CTL 6HQ D06
R 49VU AIR COND/AVNCS VENT/CTL 5HQ D05
R 122VU AIR COND/AVNCS/VENT/MONG 3HQ Y17
R 123VU AVNCS VENT/BLOWER/FAN 1HQ AD10
R 123VU AVNCS VENT/EXTC/FAN 2HQ AE02
R Subtask 21-26-43-010-094
R D. Get Access
R (1) Put the access platform in position at the access door 824.
R (2) Open the access door 824.
R 4. Procedure_________
R (Ref. Fig. 304/TASK 21-26-43-991-031)
R Subtask 21-26-43-020-081
R A. Removal of the Filter Cartridge
R (1) Release each of the four fasteners:
R (a) Move the lock (14) to the door of the body (10).
R (b) Lift the fasteners.
R (2) Push the door and lift the fasteners to fully release the door of the
R body (10).
R (3) Open the door of the body (10).
R (4) Hold the two ends of the ring (12) with the loop bowden cable.
R (5) Pull the filter (13) with the straps to disengage the bearing from
R its housing.
R (6) Remove the filter (13) from the body (10).
R Filter Cartridge R Figure 304/TASK 21-26-43-991-031
1EFF : 001-049, 101-105, 1 21-26-43Page 318 1 1 Config-2 Aug 01/05 1 1 1CES 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 2(68)