• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:37来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


R AFT Cargo-Compartment Ventilation-System - Component Location Figure 001
 1EFF : ALL 1 21-28-00Page 2 1 1 May 01/03 1 1 1CES 1


 AFT Cargo-Compartment Ventilation-System - Component Location

 Figure 002 
R 1EFF :  001-049, 051-099, 101-149, 221-221,  1 Page 321-28-00
 1224-224, 228-228,  1 May 01/05
 1  1
 1CES  1

 

 AFT Cargo-Compartment Ventilation-System - Component Location
 Figure 002A

R 1EFF : 151-199, 401-499, 1 21-28-00Page 4 1 1 Aug 01/05 1 1 1CES 1


 AFT Cargo-Compartment Ventilation-System - Component Location
 Figure 002B

R 1EFF : 201-220, 222-223, 225-227, 229-299, 1 21-28-00Page 5 1 1 Feb 01/05 1 1 1CES 1R AFT Cargo-Compartment Ventilation-System - Component Location R Figure 002C


R 1EFF : 301-399, 1 21-28-00Page 6 1 1 May 01/04 1 1 1CES 1


 3. System Description
__________________
 **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
 (Ref. Fig. 003)
 **ON A/C 151-199,
 (Ref. Fig. 003A)

R **ON A/C 401-499,
R (Ref. Fig. 003B)
 **ON A/C ALL
 A. AFT Cargo-Compartment Ventilation-System Suction from the extraction fan 35HN causes air to flow into the ventilation system of the AFT cargo compartment when the extraction fan 35HN operates on the ground or in flight. Three inlets installed along the compartment lower left-hand sidewall, direct the air towards the compartment floor area. An isolation valve 34HN is installed in distribution ducts upstream of the compartment inlets. The AFT compartment air is extracted through two outlets near the compartment ceiling on the aft end wall. The air goes through the extraction fan 35HN and an isolation valve 33HN and is discharged in the area of the outflow valve 10HL.
 B. System Performance
 (1) Flowrate
 The flowrate through the AFT cargo compartment is: Volumetric Airflow Mass Flow
 -ground 160 l/s 190 g/s,
 -flight 160 l/s 141 g/s.
 4. Power Supply
____________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 (Ref. Fig. 004)


 AFT Cargo-Compartment Ventilation - Schematic
 Figure 003

R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 21-28-00Page 8 1301-399, 1May 01/05 1 1 1CES 1R FWD Cargo-Compartment Ventilation - Schematic R Figure 003A


R 1EFF : 151-199, 1 21-28-00Page 9 1 1 Nov 01/04 1 1 1CES 1R AFT Cargo-Compartment Ventilation - Schematic R Figure 003B


R 1EFF : 401-499, 1 21-28-00Page 10 1 1 Aug 01/05 1 1 1CES 1


 AFT Cargo-Compartment Ventilation - Electrical Schematic
 Figure 004

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-28-00Page 11 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1


R  **ON A/C 401-499, 
R  (Ref. Fig. 004A) 
R  **ON A/C ALL
 5. Component Description_____________________ 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 A. Cargo Ventilation Controller (Ref. Fig. 001) The cargo ventilation controller 10HN is of a modular construction and consists of: - a chassis, - a common power supply module, - a FWD cargo ventilation module, - a FWD cargo power relay, - an AFT cargo ventilation module, - an AFT cargo power relay, - a spare module connector, - a spare power relay socket. These modules are enclosed in a metal case. They are installed on the outboard side of relay box 103VU, in the avionics compartment. The cargo ventilation controller 10HN controls and monitors the isolation valves 33HN, 34HN and the extraction fan 35HN. The controller sends a signal to ECAM and CFDS if there is a fault in the isolation valves or extraction fan. 
R  **ON A/C 401-499, 
R R R R R R R R R R R R  A. Cargo Ventilation Controller (Ref. Fig. 001) The cargo ventilation controller 10HN is of a modular construction and consists of: - a chassis, - a common power supply module, - a FWD cargo ventilation module, - a FWD cargo power relay, - an AFT cargo ventilation module, - an AFT cargo power relay, - a spare module connector, - a spare power relay socket.

 

R AFT Cargo-Compartment Ventilation - Electrical Schematic R Figure 004A
R 1EFF : 401-499, 1 21-28-00Page 13 1 1 Aug 01/05 1 1 1CES 1


R R R R R R  These modules are enclosed in a metal case. They are installed on the outboard side of relay box 103VU, in the avionics compartment. The cargo ventilation controller 10HN controls and monitors the isolation valves 33HN, 34HN and the extraction fan 35HN. The controller sends a signal to ECAM and CFDS via the air conditioning system controller (ACSC1) if there is a fault in the valves or fan. 
R  **ON A/C ALL
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 2(102)