 NOTE : Make sure that at least one of the windows in the cockpit stays
____ open during this part of the decontamination procedure.
 (1)
 Start the engine 1(2) (Ref. TASK 71-00-00-710-003).

 (2)
 On the CARGO HEAT panel 22VU push the HOT AIR pushbutton switch to the off position. (the OFF legend comes on).

 (3)
 On the AIR COND panel 30VU:

 (a)
 Make sure that:

 -
the X BLEED selector is at the AUTO position,

 -
the PACK 1 and the PACK 2 pushbutton switches are in the on position (the FAULT and the OFF legends are off).

 

 (b)
 Push the HOT AIR pushbutton switch to the on position (the FAULT and the OFF legends are off).

 (c)
 Turn the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors to the HOT position.

 

 (4)
 Move the applicable throttle control lever forward until on the upper ECAM DU: a N2 of 95% is shown.


R 1EFF : 001-003, 051-054, 301-399, 1 21-00-00Page 289 1 1 Aug 01/05 1 1 1CES 1


 (5)
 Keep this condition for 15 minutes. NOTE : During this 15 minute period you must constantly monitor the

____ duct inlet and the pack temperatures.

 (6)
 To do this you must:

 (a)
 On the ECAM control panel push the BLEED pushbutton switch.

 (b)
 On the ECAM lower DU make sure that:

 -
the pack compressor outlet temperature does not go above 230 deg. C (max.) and,

 -
the pack outlet temperature does not go above 85 deg. C (max.).

 

 (c)
 On the ECAM control panel push the COND pushbutton switch.

 (d)
 On the ECAM lower DU make sure that the duct inlet temperature does not go above 70 deg. C (max.).

 


 NOTE : If any of the temperatures go above max. you must stop the
____ procedure and do the trouble shooting of the ECS (refer to TSM, chapter 21).

R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 21-00-00-160-058-A
 R. Stage 2 Cleaning of the ECS WARNING : MAKE SURE THAT THERE ARE NO PERSONS OR EQUIPMENT NEAR THE RAM
_______ AIR OUTLETS. HOT EXHAUST GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
 CAUTION : MAKE SURE THAT THE AREA NEAR THE RAM AIR INLET IS CLEAN AND
_______ FREE FROM LOOSE ARTICLES. LOOSE ARTICLES CAN GO INTO THE RAM AIR INLET AND CAUSE DAMAGE TO EQUIPMENT.
 NOTE : Make sure that at least one of the windows in the cockpit stays
____ open during this part of the decontamination procedure.
 (1)
 Start the engine 1(2) (Ref. TASK 71-00-00-710-003).

 (2)
 On the CARGO HEAT panel 22VU push the HOT AIR pushbutton switch to the off position. (the OFF legend comes on).

 (3)
 On the AIR COND panel 30VU:

 (a)
 Make sure that:

 -
the X BLEED selector is at the AUTO position,

 -
the PACK 1 and the PACK 2 pushbutton switches are in the on position (the FAULT and the OFF legends are off).

 

 (b)
 Push the HOT AIR pushbutton switch to the on position (the FAULT and the OFF legends are off).

 (c)
 Turn the COCKPIT, the FWD CABIN and the AFT CABIN temperature selectors to the HOT position.

 

 (4)
 Move the applicable throttle control lever forward until on the upper ECAM DU: a N2 of 95% is shown.

 (5)
 Keep this condition for 15 minutes. NOTE : During this 15 minute period you must constantly monitor the

____
 duct inlet and the pack temperatures.


 (6)
 To do this you must:

 (a)
 On the ECAM control panel push the BLEED pushbutton switch.

 (b)
 On the ECAM lower DU make sure that:

 -
the pack compressor outlet temperature does not go above 230 deg. C (max.) and,

 -
the pack outlet temperature does not go above 85 deg. C (max.).

 

 (c)
 On the ECAM control panel push the COND pushbutton switch.

 (d)
 On the ECAM lower DU make sure that the duct inlet temperature does not go above 70 deg. C (max.).

 

 


 NOTE : If any of the temperatures go above max. you must stop the
____ procedure and do the trouble shooting of the ECS (refer to TSM, chapter 21).
R 1EFF : 004-049, 055-099, 101-149, 151-199, 1 21-00-00Page 291 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1


 **ON A/C ALL
 Subtask 21-00-00-860-073
 S. Aircraft Maintenance Configuration
 