4. Procedure
_________
(Ref. Fig. 501/TASK 21-23-00-991-001)
R **ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 21-23-00-720-050
A. Functional Test of the Air Extraction Duct
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Remove the plug (4) and the On the manometer: packing (3) from the forward - the pressure reads between 6 mbar pressure measurement point 1025. (0.08 psi) and 10 mbar (0.14 psi).
-discard the packing (3).
-connect the MANOMETER (EMA84)
to the forward pressure
measurement point 1025 with a
piece of silicon tubing, I/D
4.0 mm (0.157 in.), approximate
length 2.0 m (6.5 ft.).
2. Disconnect the manometer and the
silicone tubing from the forward
pressure measurement point 1025.
-put the new packing (3) in
position on the plug (4) and
install the plug (4) in the
forward pressure measurement
point 1025.
-TORQUE the plug (4) to 70
lbf.in (0.79 m.daN) maximum.
3. Remove the screw (1) and the lock On the manometer: washer (2) from the aft pressure - the pressure reads between 11 mbar measurement point 1026. (0.15 psi) and 15 mbar (0.21 psi).
-discard the lock washer (2).
-connect the MANOMETER (EMA84)
to the aft pressure measurement
point 1026 with a piece of
silicone tubing, I/D 4.0 mm
(0.157 in.), approximate length
2.0 m (6.5 ft.).
R Pressure Measurement Point - Locations Figure 501/TASK 21-23-00-991-001
1EFF : 1 1 1CES ALL 1 111 21-23-00 Page 504 Aug 01/98
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4. Disconnect the manometer and the
silicone tubing from the aft
pressure measurement point 1026.
-put the new lock washer (2) in
position on the screw (1) and
install the screw (1) in the
aft pressure measurement point
1026.
-TORQUE the screw (1) to 70
lbf.in (0.79 m.daN) maximum.
R **ON A/C 151-199, 401-499,
Subtask 21-23-00-720-050-A
A. Functional Test of the Air Extraction Duct
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Remove the plug (4) and the On the manometer: packing (3) from the forward - the pressure reads between 5 mbar pressure measurement point 1025. (0.07 psi) and 10 mbar (0.14 psi).
-discard the packing (3).
-connect the MANOMETER (EMA84)
to the forward pressure
measurement point 1025 with a
piece of silicon tubing, I/D
4.0 mm (0.157 in.), approximate
length 2.0 m (6.5 ft.).
2. Disconnect the manometer and the
silicone tubing from the forward
pressure measurement point 1025.
-put the new packing (3) in
position on the plug (4) and
install the plug (4) in the
forward pressure measurement
point 1025.
-TORQUE the plug (4) to 70
lbf.in (0.79 m.daN) maximum.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-23-00Page 505 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------