(c)
On the ECAM control panel push the COND pushbutton switch.
(d)
On the ECAM lower DU make sure that the duct inlet temperature is not more than 70 deg. C (max).
NOTE : If any of the temperatures go above max. you must stop the
____ procedure and do the trouble shooting of the ECS (refer to TSM, chapter 21).
R 1EFF : 004-049, 055-099, 101-149, 151-199, 1 21-00-00Page 258 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
Subtask 21-00-00-860-065
X. Aircraft Maintenance Configuration
(1)
Do the Procedure to Stop the APU
-
(Ref. TASK 49-00-00-860-004) or,
-
(Ref. TASK 49-00-00-860-006) or,
-
(Ref. TASK 49-00-00-860-009).
(2)
If there is smoke in the cockpit or cabin then you must do the decontamination procedure again.
(3)
If after 20 minutes, with the recirculation fans running, you can still smell the oil, you must replace the recirculation filters (Ref. TASK 21-21-41-000-001) (Ref. TASK 21-21-41-400-001).
(4)
Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
Subtask 21-00-00-865-068
Y. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 401-499,
49VU AIR COND/TEMP CTL/SYS 1 CHAN B/28VDC 52HH D08
**ON A/C ALL
121VU APU/APU/CTL 2KD L42
121VU APU/ECB/SPLY 1KD L41
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 122VU AIR COND/AFT CARGO VENT/FAN 30HN S22 122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22 122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21 122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22
R 1EFF : ALL 1 21-00-00Page 259 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21
122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21
122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 22HH Y20
R
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
R 122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC 4HH Y19
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18
R **ON A/C 106-149, 303-399,
R 122VU 4HH Y19
R **ON A/C 401-499,
R 122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 53HH W22
R 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 55HH W21
R 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 49HH X22
R 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 51HH X21
R 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 56HH Y21
R 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC 54HH Y20
122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC 50HH Y18
R
R 1EFF : ALL 1 21-00-00Page 260 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL
Subtask 21-00-00-865-084
Z. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION FIN LOCATION -------------------------------------------------------------------------------122VU AIR COND/AFT CARGO VENT/CTL AND/MONG 31HN 20 S or alternative location :-
49VU AIR COND/AFT CARGO/VENT/CTL & MONG 31HN 07 C
**ON A/C 001-049, 101-105, 151-199,
Subtask 21-00-00-210-053-A
AA. Post Cleaning and Inspection of the ECS
WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING
_______ SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING : DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
_______
COOL TO PREVENT BURNS.
(1)
Remove, clean and install:
(a)
The water extractors 10HM8, 11HM8 and the water extractor drain lines (Ref. TASK 21-52-16-000-001), (Ref. TASK 21-52-16-400-001) and (Ref. CMM 215204).
(b)
The water injectors 20HM and 21HM (Ref. TASK 21-52-42-000-001), (Ref. TASK 21-52-42-400-001) and (Ref. CMM 215234).