-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the AIR COND menu page: On the MCDU:
- push the line key adjacent to - the CAB TEMP CONT menu page comes on.
the TEMP CTL indication.
2. On the CAB TEMP CONT menu page:
- push the line key adjacent to - the CAB TEMP CONT TEST page comes on.
the TEST indication. - the message PACK 1 AND 2 SELECT OFF
comes on
3. On the CAB TEMP CONT TEST page:
- push the line key adjacent to - the message IN PROGRESS MAX 300 S
the CONTINUE indication. comes on, then the messages TEST OK
and END OF TEST comes on.
- push the MCDU MENU key. - the MCDU MENU page comes on.
4. On the MCDU MENU page:
- push the line key adjacent to - the CFDS page comes on.
the CFDS indication.
5. On the CFDS page:
- push the line key adjacent to - the AVIONICS STATUS page with no TEMP
the AVIONICS STATUS. CTL (CLASS 3) message comes on.
NOTE : Ignore the CLASS 3 failures on____
the CAB TEMP CONT CLASS 3 FAULTS
page.
1EFF : ALL 1 21-21-00Page 504 1 1 Aug 01/05R 1 1 1CES 1
5. Close-up
________ Subtask 21-21-00-860-055
A. Aircraft Maintenance Configuration
(1)
On the panel 30VU push the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
(2)
On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.
(3)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
FILTER - RECIRCULATION (4012HM,4013HM) - SERVICING
__________________________________________________
TASK 21-21-41-920-002
Scheduled Replacement of the Recirculation Filter 4012HM (4013HM)
1. Reason for the Job
__________________
Refer to the MPD TASK: 212141-01
2. Job Set-up Information
______________________
A. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
3 recirculation filter 21-21-02 49A-020 3 recirculation filter 21-21-02 49A-020A 3 recirculation filter 21-21-02 49A-020B 3 recirculation filter 21-21-02 49A-020C 3 recirculation filter 21-21-02 49B-020
R 3 recirculation filter 21-21-02 49B-020A
R 3 recirculation filter 21-21-02 49B-020B 3 recirculation filter 21-21-02 49B-020C 3 recirculation filter 21-21-02 49B-020D 3 recirculation filter 21-21-02 49C-020 3 recirculation filter 21-21-02 49C-020A 3 recirculation filter 21-21-02 49C-020B
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
21-21-41-000-001 Removal of the Recirculation Filter 4012HM (4013HM) 21-21-41-400-001 Installation of the Recirculation Filter 4012HM (4013HM) 21-21-41-991-003 Fig. 301
3. Job Set-up
__________
Subtask 21-21-41-420-054
A. Not Applicable
4. Procedure
_________