__________________
 Self Explanatory
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  warning notice
R  EFF : 001-049, 101-105, 107-107, 151-199, 49-00-00Page 508 201-210, Config-2 Aug 01/05
 CES  B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
23-44-00-860-001  Operation of the Service Interphone System 
 24-42-00-861-001  Energize the Ground Service Network from the External 
 Power 
 24-42-00-862-001  De-energize the Ground Service Network Supplied from 
 the External Power 
 26-22-00-710-001  Operational Test of the APU Fire-Extinguishing 
 Loop/Squib 
 29-00-00-864-001  Put the Related Hydraulic System in the Depressurized 
 Configuration before Maintenance Action 
 29-14-00-614-002  Pressurization of the Hydraulic Reservoirs through 
 the Ground Connector 
 31-32-00-860-001  Procedure to Get Access to the SYSTEM REPORT/TEST 
 Menu Page 
 31-60-00-860-001  EIS Start Procedure 
 49-00-00-710-009  Self-Test of the ECB (131-9(A)) 
 52-41-00-010-002  Open the Avionics Compartment Doors for Access 
 52-41-00-410-001  Close the APU Doors after Access 
 3. Job Set-up__________ 
 Subtask 49-00-00-941-071 
 A. Safety Precautions
 WARNING : WHILE THE APU OPERATES, DO NOT GO INTO THESE AREAS:
_______
 -
THE AREA BEHIND THE APU EXHAUST DUCT: 25m (82ft.) REARWARD OF
 THE DUCT, MORE THAN 3m (10ft.) ABOVE THE GROUND, AND THE WIDTH
 OF THE HORIZONTAL STABILIZER
 -
THE AREA AROUND THE APU AIR-INTAKE: 2m (7ft) AROUND THE
 INTAKE
 -
THE AREA OF THE OIL-COOLER OUTLET.
 THERE IS A RISK OF INJURY IF YOU GO INTO THESE AREAS.
 (1)
 Make sure that the danger areas are clear of persons and/or equipment.
 (2)
 Close the APU access doors 315AL and 316AR (Ref. TASK 52-41-00-410-001).
R  EFF : 001-049, 101-105, 107-107, 151-199, 49-00-00Page 509 201-210, Config-2 Aug 01/05
 CES
 (3) If an emergency or a malfunction occurs during operation of the APU, do the emergency shutdown procedure immediately. You can start the emergency shutdown from:
 -
the APU FIRE PUSH pushbutton switch on the panel 20VU.
 -
the APU SHUT OFF pushbutton switch on the panel 108VU.
 NOTE : Do the emergency shutdown immediately if fire, smoke, unusual
____
 noise, fuel or oil leakage occurs.
 Subtask 49-00-00-860-096
 B. Aircraft Maintenance Configuration
 (1)
 Open the access door 811 (Ref. TASK 52-41-00-010-002).
(a) Put the warning notice in position on the opened access door 811 which tells persons not to close the door.
 (2)
 Energize the aircraft electrical circuits.
 (a)
 Energize the ground service network
 (Ref. TASK 24-42-00-861-001).
 (b)
 On the ELEC section on the panel 35VU:
 -make sure that the BAT 1 and BAT 2 pushbutton switches are in the auto position (the ON and FAULT legends are OFF).
 (3)
 Make sure that there is sufficient fuel in the A/C fuel system.
 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).
 (5)
 Make a service interphone connection from the cockpit to the APU compartment area (Ref. TASK 23-44-00-860-001).
 (6)
 On the AIR COND section of the panel 30VU:
 -
make sure that the APU BLEED pushbutton switch is in the off position (the ON and FAULT legends are off).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER1(134)