On the panel 25VU:
-
the ON legend in the APU STARTpushbutton switch comes on.
 On the panel 35VU:
 -DC V indication decreases.
 On the lower ECAM display:
 -N indication increases.
On the lower ECAM display:
-N% indication increases.
 -EGT increases.
-stable and surge free with an increase of EGT and N indications.
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- check at 50% N.  On the panel 35VU: - DC V indication increases as the 
 starter motor de-energizes. 
 On the lower ECAM display: - N indication increases. 
 - EGT indication decreases. 
 - check at 95% N.  On the panel 25VU: - the ON legend in the START pushbutton switch goes off. - the AVAIL legend in the START pushbutton switch comes on. 
 On the lower ECAM display: - AVAIL indication comes on. 
 - EGT in limits. 
 - N indication increases to 99%. 
 - APU GEN (amber) OFF (white) comes on. 
 10. On the panel 35VU: - push the APU GEN pushbutton switch to the ON position.  On the panel 35VU:- the OFF legend in the APU GENpushbutton switch goes off. 
 On the lower ECAM display: - the generator load, voltage and frequency indication are in the specified limits (no amber or red indication). 
 11. On the panel 30VU: - push the APU BLEED pushbutton switch to the ON position.  On the panel 30VU:- the ON legend in the APU BLEEDpushbutton switch comes on. 
 On the lower ECAM display: - momentarily there is a small increase in EGT. 
 12. On the panel 30VU: - push the PACK1 and PACK2 pushbutton switches to the ON position. On the panel 30VU:- the OFF legends in the PACK1 andPACK2 pushbutton switches go off. 
 On the lower ECAM display:
 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
13. On the panel 30VU: 
-release the PACK1 and PACK2 pushbutton switches to OFF. 
14. On the panel 35VU: 
-push the APU GEN pushbutton switch to the OFF position. 
15. On the panel 25VU: 
-release the APU MASTER SW pushbutton switch. 
16. On the MCDU 1(2) AVIONICS STATUS page:
 -there is no APU related indication.
 -RPM stays at 100% plus/minus 1%.
 -EGT changes to the pneumatic load.
On the panel 30VU:
-
the OFF legends in the PACK1 andPACK2 pushbutton switches come on.
On the panel 35VU:
-
the OFF legend in the APU GENpushbutton switch comes on.
 On the lower ECAM display:
 -APU GEN (amber) OFF (white) indication comes on.
On the panel 25VU:
-
the AVAIL legend in the STARTpushbutton switch goes off (N < 95%).
On the lower ECAM display:
 -
the AVAIL indication goes off, when the AVAIL legend in the START pushbutton switch goes off.
 -RPM decreases to 75% and stays at 75% for 60 seconds (cool down).
 -APU BLEED indicator goes off.
 -EGT and N indicator go off, when ECB powered down.
 NOTE : To make sure that the air intake
____ fully closes, wait for amber XX indication of RPM and EGT.
R **ON A/C 063-099, 401-499,
 Subtask 49-00-00-710-053-A
 A. Operational Test of the APU
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 35VU: 
-push the BAT1 and BAT2 pushbutton switches to the AUTO position. 
2. On the panel 11VU: 
-push the BLEED pushbutton 
switch on the ECAM panel.
 3. On the panel 30VU: 
-push the APU BLEED pushbutton switch to the OFF position. 
4. On the panel 30VU: 
-set the APU X BLEED switch to the AUTO position. 
5. On the panel 40VU: 
-push the fuel X FEED pushbutton switch to the CLOSED position. 
6. On the panel 25VU: 
-push the APU MASTER SW pushbutton switch to the ON position.
 7. On the panel 11VU: 
-push the APU pushbutton switch on the ECAM panel. 
On the panel 35VU:
-DC V battery indicators show eachbattery voltage (28V maximum, 21Vminimum).
On the ECAM panel display:
-
the BLEED system page comes on.
On the panel 30VU:
-
the ON legend in the APU BLEEDpushbutton switch goes off.
On the lower ECAM display:
-
the X BLEED valve is in the closedposition.
On the panel 40VU:
-
the ON legend in the fuel X FEEDpushbutton switch goes off.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER1(121)