DC Surge simulation
Normal transients
36 VDC, 100 ms
35 VDC, 200 ms
34 VDC, 300 ms
18.5 VDC, 5s
Test 3
Voltage surge:
Normal transients
AC Surge simulation at 400 Hz
160 VAC RMS, 30 ms
71 VAC RMS, 15 ms
156 VAC RMS, 50 ms
80 VAC RMS, 30 ms
148 VAC RMS, 100 ms
86 VAC RMS, 50 ms
140 VAC RMS, 200 ms
AC Surge simulation at 400 Hz
36.5 VAC RMS, 30 ms
16.1 VAC RMS, 15 ms
35.6 VAC RMS, 50 ms
18.2 VAC RMS, 30 ms
33.8 VAC RMS, 100 ms
19.5 VAC RMS, 50 ms
32 VAC RMS, 200 ms
AC Surge simulation at 360 Hz and 800 Hz
160 VAC RMS, 30 ms
71 VAC RMS, 15 ms
156 VAC RMS, 50 ms
80 VAC RMS, 30 ms
148 VAC RMS, 100 ms
86 VAC RMS, 50 ms
140 VAC RMS, 200 ms
DC Surge simulation
40 VDC, 30 ms
17 VDC, 15 ms
39 VDC, 50 ms
19.5 VDC, 30 ms
37 VDC, 100 ms
21 VDC, 50 ms
35 VDC, 200 ms
DC Surge simulation
Abnormal transients
36VDC,1s
33VDC,3s
0 VDC, 5 s
Test 4
Voltage surge:
Abnormal transients
AC Surge simulation at 400 Hz
180 VAC RMS, 100 ms
148 VAC RMS, 1 s
0 VAC RMS, 5 s
AC Surge simulation
41.1 VAC RMS, 100 ms
33.8 VAC RMS, 1 s
0 VAC RMS, 5 s
AC Surge simulation
180 VAC RMS, 100 ms
148 VAC RMS, 1 s
0 VAC RMS, 5 s
DC Surge simulation
46 VDC, 100 ms
38 VDC, 1 s
0 VDC, 5 s
Test 5
High voltage spike test
Switching Transients
Fully compliant with Appendix 1
Figure A
Figure B
Test 6
Switching Transients
Switching Transients
Nominal Voltage = 115; Lowline Voltage = 111
Fully compliant with Appendix 1
Figure A
Figure B
Switching Transients
Fully compliant with Appendix 1
Figure A
Figure B
Switching Transients
Fully compliant with Appendix 1
Figure A
Figure B
Switching Transients
Fully compliant with Appendix 1
Figure A
Figure B
Ripple on DC Network, with a frequency
characteristic corresponding with the frequency
spectrum envelope mentioned in Figure 8 up to
1kHz.
Test 7
Voltage modulation
Modulation frequency and index, fully
compliant with Figure 4-A
Modulation frequency and index, fully compliant
with Figure 4-A
Modulation frequency and index, fully compliant with
Figure 4-A
DC Voltage square pulse
Compliant with Figures 7-A and 7-B
Starting inrush current at DC equipment powerup
Figure 14
Test 8
Frequency excursions
Frequency excursions Abnormal operations
Figure 5
Limits 1 and 4
Frequency excursions Abnormal operations
Figure 5
Limits 1 and 4
Frequency excursions Normal and emergency
operations
Figure 5
Limits 2 and 3
Ripple on DC Network, with a frequency
characteristic corresponding with the frequency
spectrum envelope mentioned in Figure 8 up to
1kHz.
N/A
Test 9
Frequency modulation
Modulation frequency and deviation, fully
compliant with Figure 6
Modulation frequency and deviation, fully
compliant with Figure 6
Modulation frequency and deviation, fully compliant
with Figure 6
N/A N/A
Test 10
Distorted voltage
THD generation compliant with paragraph
2.4.2.6.1 of the Standard, test condition 2
N/A
THD generation compliant with paragraph 2.4.2.6.1 of
the Standard, test condition 2 and 3
N/A N/A
Table A-2 ABD0100.1.8 Compliance Matrix
ABD0100.1.8 Compliance Matrix
DC POWER SIMULATION FOR A380 DC EQUIPMENT CONNECTED TO
CONVENTIONAL 28 VDC NETWORK
Table D
––––––––––––––––––––––––––––––– N O T P R O V I D E D –––––––––––––––––––––––––––
N O T P R O V I D E D
M163000-01 Rev B A-5
INDEX
A
ABD100 Test Suite, Description..............1-1
Activation Code .......................................2-4
Authorization Request Code ...................2-4
D
Deactivation Code
Transfer License................................. A-4
Demo Mode.............................................2-4
Disclaimer ................................................. iv
Duration
of Tests..............................................2-16
E
Error Checking ......................................2-18
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
航空资料2(186)