Table A–1 Summary of In-Rush Current Tests
M163000-01 Rev B A-3
Appendix Elgar ABD100 Test Suite
A.3 Transferring the Software License
A single license authorizes the ABD100 Test Suite software to be run on only one
computer. If there is a need to run the software on a different computer, the License must
be properly deactivated on the first computer and then reactivated on the alternate
computer. (The software itself does not need to be uninstalled from the first computer
and can continue to be used in Demo Mode for training purposes).
To transfer the software license, click the License Options in the Standards menu. In the
License Activator window click the Transfer License button. A message window will
provide a warning that the license will be permanently deactivated on that machine, and it
will ask for confirmation to continue the deactivation process. Once the Yes button is
clicked, a message window will confirm that deactivation took place and will provide a
Deactivation Code.
It is crucial that the Deactivation Code be remembered, as it will be needed to reactivate
the license on the computer to which the software is transferred. It is advisable to copypaste
the code into a word processing document to be kept as a record, although a log
file named DEACTIVATION_LOG.txt with the deactivation code will be created in the
SWCS application directory.
Install the SWCS application software and the ABD100 Library files on the alternate
computer. Follow the procedures for running the licensed Test Administrator, except give
the Deactivation Code to the Elgar representative who will first verify that it is a valid code
and then provide a new Activation Code.
A-4 M163000-01 Rev B
Elgar ABD100 Test Suite Appendix
Table A Table B Table C Table E
NOTE: In this table,
references to Figures,
Appendix, and
Paragraph number,
apply to ABD0100.1.8,
Issue D.
AC POWER SIMULATION FOR A380 AC
EQUIPMENT CONNECTED TO 115 VAC RMS /
400 Hz SUPPLY SOURCE
Single phase and 3-phase power
simulation.
AC POWER SIMULATION FOR A380 AC
EQUIPMENT CONNECTED TO 26 VAC RMS /
400 Hz SUPPLY SOURCE
Single phase and 3-phase power
simulation.
AC POWER SIMULATION FOR A380 AC
EQUIPMENT CONNECTED TO 115 VAC RMS /
VARIABLE FREQUENCY (360 - 800 Hz) SUPPLY
SOURCE
Single phase and 3-phase power
simulation.
DC POWER SIMULATION FOR A380 DC
EQUIPMENT CONNECTED TO NBPT (No Break
Power Transfer) 28 VDC NETWORK
Test 1
Steady-state voltage
and frequency power
simulation
Normal & emergency operation at 400 Hz
Nominal single phase: 104 to 122 VAC RMS
Low-line single phase: 100 to 118 VAC RMS
Nominal 3-phase: 105.5 to 120.5 VAC RMS
Low-line 3-phase: 101.5 to 116.5 VAC RMS
Normal & emergency operation at 400 Hz
Nominal single-phase: 23 to 28 VAC RMS
Normal & emergency operation at 360 Hz and 800 Hz
Nominal single phase: 104 to 122 VAC RMS
Low-line single phase: 100 to 118 VAC RMS
Nominal 3-phase: 105.5 to 120.5 VAC RMS
Low-line 3-phase: 101.5 to 116.5 VAC RMS
DC
Max. (Normal & emergency operations): 30.3 VDC
Min. (Normal & emergency operations): 25.5 VDC
emergency operation: 17 VDC
DC
Max. (Normal & emergency operations): 32 VDC
Min. (Normal & emergency operations): 24 VDC
emergency operation: 18.5 VDC
Test 2
Abnormal steady-state
voltage and frequency
power simulation
Normal & emergency operation at 400 Hz
Nominal single phase: 96 to 130 VAC RMS
Low-line single phase: 92 to 126 VAC RMS
Nominal 3-phase: 96 to 130 VAC RMS
Low-line 3-phase: 96 to 126 VAC RMS
Normal & emergency operation at 400 Hz
Nominal single-phase: 21 to 30 VAC RMS
Normal & emergency operation at 360 Hz and 800 Hz
Nominal single phase: 96 to 130 VAC RMS
Low-line single phase: 92 to 126 VAC RMS
Nominal 3-phase: 965 to 130 VAC RMS
Low-line 3-phase: 92 to 126 VAC RMS
DC
Max. (Normal & emergency operations): 32.5 VDC
Min. (Normal & emergency operations): 23.5 VDC