80-00 4) Visually inspect the starter relay (if battery at the front), check attach fittings, lugs and terminal covers. 100
FINAL STEPS 000 X X
24-40 1) Disconnect the external power supply
source (if installed). 200
52-40 2) Install sealed inspection doors 513, 514 - refer to 52-40-00 201. 500
57-30 3) Install wing tip 517 (if not riveted) - refer to 57-30-00 201. 500
52-40 4) Install sealed inspection doors 613, 614 - refer to 52-40-00 201. 600
57-30 5) Install wing tip 617 (if not riveted) - refer to 57-30-00 201. 600 x
52-40 6) Install baggage compartment bottom
door 242. 200 X
52-40 7) Install landing gear hydraulic generator
access door 238L. 200
52-40 8) Install inspection doors 235L, 235R. 200
52-40 9) Install battery access door 243 (battery at the rear). Check that it is correctly locked. 200 X X
52-40 10) Install inspection doors 211L, 211R, (if
installed). 200
24-30 11) Connect the battery, lubricate the terminals 000 X X
- refer to 24-30-02 201.
52-40 12) Install inspection door 211 R (if front battery option). 200 X X
52-40 13) Install firewall-mounted inspection doors 200
212L and (if installed) 212R.
NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
AHAA
Validity : S / N 1 - 9999 05-20-01 Page 247
(IA) JUN 01
ATA OPERATIONS Area INSPECTIONS
1st
25 hrs 50
hrs 100
hrs Major Ann. Other
52-40 14) Install inspection doors 213L, 214 and (if installed) 213R. 200 xo x xx x x x x x x x xl
52-40 15) Install inspection door 214 (if installed). 200
53-00 Post-MOD. 151 200 NOTE 1
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 1(99)