NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
ATA OPERATIONS Area INSPECTIONS
1st
25 hrs 50
hrs 100
hrs Major Ann. Other
32-20 7) Thoroughly examine the whole nose
landing gear mount. Fluorescent dye penetrant inspect the attach fittings and mount for cracks and distortion ; check for protection and absence of interference -refer to 32-20-01 201. 700 X
32-20 8) Check that the nose landing gear mount is correctly attached to the firewall. Check the red painted marks on the bolts for
alignment. 700 X X 0 NOTE 1
32-20 9) Visually inspect the nose landing gear
wheel-centering device. 700 X X 0 NOTE 1
32-20 10) Visually inspect the nose landing gear
interconnection system and check the
levers for condition. 700 X X
32-30 Extension and retraction
32-30 1) Visually inspect the landing gear
microswitches, electrical wiring and attach fittings - refer to 32-60-01 201,
32-30-07 201. 700 X X 0 NOTE 1
32-30 2) Visually inspect the landing gear relays, electrical wiring and attach fittings. 200 X
32-30 3) Visually inspect the landing gear hydraulic generator and check for leaks. Check fluid level - refer to 12-13-03 301. 200 X X 0 NOTE 1