NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
AHAA
Validity : S / N 1 - 9999 05-20-01Page 215
(IA) JUN 01
ATA OPERATIONS Area INSPECTIONS
1st
25 hrs 50
hrs 100
hrs Major Ann. Other
28-10 6) Perform an operational test of the R.H. fuel tank cap and check the seal condition - refer to 28-10-00 301. 600 X X
28-10 7) Inspect the R.H. fuel tank for condition, clean if necessary - refer to 28-10-00 601. 600 X
28-10 8) Inspect the draining holes located on the non-sealed ribs of the R.H. fuel tank for partial or total obstruction with sealing
compound or any other deposit. 600 X
28-10 9) Inspect the draining holes located under the low level detector box (if installed) of the 600 X
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 1(69)