27-50 7) Visually inspect (do not remove) the R.H. flap control rods. 600    X X 
27-50 8) Remove and clean R.H. flap control
bellcrancks. Perform a detail examination. 600    X  1000 hrs
 Lubricate. Install.       
28-00 FUEL       
28-00 General       
28-00 1) Inspect the fuel system for tightness (from the electric pump to the power plant equipment) - refer to 28-00-00 201. 000   X X 0 NOTE 1
28-10 Storage       
28-10 1) Perform an operational test of the L.H. fuel tank cap and check the seal condition - refer to 28-10-00 301. 500    X X 
28-10 2) Inspect the L.H. fuel tank for condition - refer to 28-10-00 601. 500    X  
28-10 3) Inspect the draining holes located on the non-sealed ribs of the L.H. fuel tank for partial or total obstruction with sealing
compound or any other deposit. 500    X  
28-10 4) Inspect the draining holes located under the low level detector box (if installed) of the 500    X  
 L.H. fuel tank for partial or total obstruction
with sealing compound or any other deposit.       
28-10 5) Visually inspect the L.H. fuel tank air vent pipes for condition, security and
obstruction. 500    X X 

NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
AHAA
Validity : S / N 1 - 9999 05-20-01Page 215
(IA) JUN 01
 

ATA OPERATIONS Area INSPECTIONS
   1st
25 hrs 50
hrs 100
hrs Major Ann. Other
28-10 6) Perform an operational test of the R.H. fuel tank cap and check the seal condition - refer to 28-10-00 301. 600    X X 
28-10 7) Inspect the R.H. fuel tank for condition, clean if necessary - refer to 28-10-00 601. 600    X  
28-10 8) Inspect the draining holes located on the non-sealed ribs of the R.H. fuel tank for partial or total obstruction with sealing
compound or any other deposit. 600    X  
28-10 9) Inspect the draining holes located under the low level detector box (if installed) of the 600    X  
 