NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
ATA OPERATIONS INSPECTIONS
Area 1st
25 hrs 50
hrs 100
hrs Major Ann. Other
52-00 DOORS
52-10 Access doors
52-10 1) Visually inspect the cabin access doors, check the structure, the transparent
material condition and check for distortion and cracks. 200 X X
52-10 2) Check the gas struts, hinges, seals, locks, rings and latches for condition. 200 X X
52-10 3) Thoroughly examine and fluorescent dye penetrant inspect the steel latches for
cracks, check for distortion and
interference. 200 2000 hrs
52-10 4) Check the small window(s) (if installed) for operation and check the seal(s) for
condition. 200 X
52-10 5) Partially debond the insulating canvas from the door lower area, thoroughly inspect the locking mechanisms. Lubricate - refer to 200 X
12-21-02 201 and rebond the canvas.
52-10 6) Check the hooks and locks for adjustment and operation - refer to 52-10-00 201. 200 X
52-30 Cargo doors
52-30 1) Visually inspect cargo door (baggage
compartment) 219 and its seal. 200 X X
52-40 Inspection doors
52-40 1) Check the ground power receptacle door 200 X
216L (if installed) for condition and correct locking, check the location and condition of the label on the door inside (if installed).
53-00 FUSELAGE
53-00 General
53-00 1) Visually inspect the firewall (front face) for loose rivets, distortion, cracks and evidence of corrosion. 100 X
Inspect equipment for security.