ATA OPERATIONS Area INSPECTIONS
1st
25 hrs 50
hrs 100
hrs Major Ann. Other
24-00 ELECTRICAL POWER
24-00 General
24-00 1) Visually inspect the battery relay (battery at the rear) and (if installed) the ground power unit relay. Check attachments, lugs and terminal covers. 200 X
24-00 2) Visually inspect all cable connections under the floor, in the rear fuselage, under the instrument panel and on the front table. 200 X X
Replace cables if damaged. Inspect cables for routing, clamp security, lugs and cleanliness.
24-00 3) Visually inspect all cable connections on the nose and main landing gears. 700 X X
Replace cables if damaged. Inspect cables for routing, clamp security, lugs and cleanliness.
24-00 4) Visually inspect all cable connections in the 500 X X
L.H. wing.
Replace cables if damaged. Inspect cables for routing, clamp security, lugs and cleanliness.
24-00 5) Visually inspect all cable connections in the 600 X X
R.H. wing.
Replace cables if damaged. Inspect cables for routing, clamp security, lugs and cleanliness.
24-00 6) Visually inspect the battery relay and the ground power unit relay (front battery
option). Check attachments, lugs and
terminal covers. 100 X
24-00 7) Check all cable connections to engine and accessories, engine mount, firewall. 100 X X
Replace cables if damaged. Inspect cables for routing, clamp security, cleanliness, lugs and terminal covers.
NOTE 1 : If a 100-hr. inspection has been carried out during the last 3 months, do not perform the operations identified with a "0" unless the annual inspection replaces a 100-hr. inspection. For US registered aircraft, perform all operations.
AHAA
Validity : S / N 1 - 9999 05-20-01 „A) Page 208
JUN 011
ATA OPERATIONS Area INSPECTIONS
1st
25 hrs 50
hrs 100
hrs Major Ann. Other
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 1(62)