     18 months maxi
mum,
. check on test bench every 3 years for
equipment with
     French type approval
prior to January 1,
1980 - refer to GSAC
     Instruction bulletin
     P-04-30.).
 34 Altimeter  Calibration Must be performed by an
  Encoding altimeter  Refer to approved radio center in
  Altitude encoder  remarks compliance with the
regulation in force in the
country of use. Example :
     FAR Part 91.411 and
     91.413 = 24 months.
 34 Transponder  Calibration
Refer to
remarks Must be performed by an approved radio center in compliance with the regulation in force in the country of use. Example :
     FAR Part 91.411 and
     91.413 = 24 months.
Z00.N6069207220 35 PURITAN BENNETT  Operational 
OPT10 062200  oxygen masks  test and
detailed 
Z00. N6069207221    inspection 
OPT10 062300    every 
Z00.N6069207228    2 years.
Overhaul
every 
    4000 hrs 

ABAA
Validity : S / N 1 - 9999 05 10-00Page 5
(CA) JUN 01
 

SOCATA
PART NUMBER ATA EQUIPMENT
AND UPPER
ASSEMBLY(IES) TIME LIMIT OPERATING
LIMIT REMARKS
Z00.N6069207222 35 PURITAN BENNETT  3 years / Hydrostatic test
OPT10 062101  oxygen cylinder +
pressure reducer  4000 hrs 
Z00.N6069207222 35 PURITAN BENNETT 24 years  
OPT10 062101  oxygen cylinder   
Z00.N6027217228 35 EROS oxygen masks  Operational 
Z00.N6027217233    test and
detailed
inspection
every 
    2 years. 
    Overhaul
every 
    6 years 
Z00.N6027217230 35 EROS oxygen cylinder +  3 years Hydrostatic test
OPT10 061701  pressure reducer   
Z00.N6027217230 35 EROS oxygen cylinder 24 years  
OPT10 061701     
Z00.N6018157232 37 AIRBORNE filter 1J4-7 for : Replacement
of filter  
OPT10 A90401  Vacuum system 1 year /  
OPT10 A90402   500 hrs  
 