- PRESS CONTROLLER 2 (37) or,
- PRESS CONTROLLER 2 (38) or,
- PRESS CONTROLLER 2 (39) or,
- PRESS CONTROLLER 2 (40) or,
- PRESS CONTROLLER 2 (41) or,
- PRESS CONTROLLER 2 (45) or,
- PRESS CONTROLLER 2 (46) or,
- PRESS CONTROLLER 2 (47) or,
- PRESS CONTROLLER 2 (49) or,
- PRESS CONTROLLER 2 (53) or,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 214
Aug 01/03R CES
- PRESS CONTROLLER 2 (58) or,
- PRESS CONTROLLER 2 (61),
- replace the CONTROLLER-CABIN PRESSURE 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 215
Aug 01/03R
CES
TASK 21-31-00-810-807
Outflow Valve Fault (05), (11), (24), (25), (26), (29), (60)
1. Possible Causes
_______________
- VALVE-OUTFLOW (10HL)
- VALVE-OUTFLOW (10HL), AUTO MOTOR 1
- VALVE-OUTFLOW (10HL), FEEDBACK ASSEMBLY
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-31-00-710-002 Operational Test of the Pressure Control and
Monitoring AMM 21-31-51-000-001 Removal of the Outflow Valve 10HL (From Inside) AMM 21-31-51-000-003 Removal of the Outflow Valve (10HL) - Auto Motor
10HL-3 (10HL-4)
AMM 21-31-51-000-005 Removal of the Outflow Valve (10HL) - Feedback
Assembly 10HL-6 AMM 21-31-51-000-006 Removal of the Outflow Valve 10HL (From Outside) AMM 21-31-51-400-001 Installation of the Outflow Valve 10HL (From Inside) AMM 21-31-51-400-003 Installation of the Outflow Valve (10HL) - Auto Motor
10HL-3 (10HL-4) AMM 21-31-51-400-005 Installation of the Outflow Valve (10HL) - Feedback Assembly 10HL-6 AMM 21-31-51-400-006 Installation of the Outflow Valve 10HL (From Outside)
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
4. Fault Isolation
_______________
A. If one of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, CLASS 3 FAULTS and/or the test gives one of the maintenance messages which follow,
- OUTFLOW VALVE (05),
- OUTFLOW VALVE (11),
- OUTFLOW VALVE (24),
- OUTFLOW VALVE BLOCKED (29) or,
- OUTFLOW VALVE (60):
- replace the VALVE-OUTFLOW (10HL), AUTO MOTOR 1 (Ref. AMM TASK 21-31-51-000-003) and (Ref. AMM TASK 21-31-51-400-003).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 216
Aug 01/03R CES
(1) If the fault continues:
- replace the VALVE-OUTFLOW (10HL) (Ref. AMM TASK 21-31-51-000-001) and (Ref. AMM TASK 21-31-51-400-001) or (Ref. AMM TASK 21-31-51-000-006) and (Ref. AMM TASK 21-31-51-400-006).
B. Test Result
NOTE : This procedure is only applicable for Outflow Valve Part Numbers
____
9023-15703 and previous.
(1) If the test gives the maintenance message,
OUTFLOW VALVE (25), or
OUTFLOW VALVE (26):
- replace the VALVE-OUTFLOW (10HL), FEEDBACK ASSEMBLY (Ref. AMM TASK 21-31-51-000-005) and (Ref. AMM TASK 21-31-51-400-005).
C. Test Result
NOTE : This procedure is only applicable for Outflow Valve Part Number
____
20790-01AA and onwards.
(1) If the test gives the maintenance message,
OUTFLOW VALVE (25), or
OUTFLOW VALVE (26):
- replace the VALVE-OUTFLOW (10HL) (Ref. AMM TASK 21-31-51-000-001) and (Ref. AMM TASK 21-31-51-400-001).
D. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 217
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(95)