Monitoring AMM 21-31-34-000-001 Removal of the Cabin Pressure Controller (11HL,12HL) AMM 21-31-34-400-001 Installation of the Cabin Pressure Controller
(11HL,12HL) AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -Electronics Module 10HL-1 (10HL-2) ASM 21-31/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
4. Fault Isolation
_______________
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT and/or the test gives the maintenance message,
- PRESS CONTROLLER 1 (51):
- swap the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(1) If the fault moves with the CPC 1:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(a) Replace the CONTROLLER-CABIN PRESSURE 1 (11HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 276
Aug 01/02R CES
(2) If the fault does not move with the CPC 1:
- swap back the CPC 1 (11HL) and the CPC 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(a) Replace the VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 1 (Ref. AMM TASK 21-31-51-000-002) and (Ref. AMM TASK 21-31-51-400-002).
NOTE : The electronic module 1 is connected to the electrical
____
connector 10HL-A.
(3) If the fault continues:
(a) do a check and repair the wiring from the:
- CPC 1 controller (11HL-AA) pins 7A, 8A, 9A and 10A to the OFV connector (10HL-A) pins R, P, N and M (Ref. ASM 21-31/02).
(b) Do a check of the earthing resistance at the return ground connections (Ref. AMM 21310076000100) on:
- the CPC 1 connector 11HL-AC, pin 2 and on,
- the electronic module 1 connector 10HL-A, pin J.
NOTE : The resistance must be smaller than 20 m.ohms.
____
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-31-00∞∞∞∞∞∞∞∞∞∞Page 277
Aug 01/02R
CES
TASK 21-31-00-810-838
Cabin Pressure Controller 2 Fault (51)
1. Possible Causes
_______________
- CONTROLLER-CABIN PRESSURE 2 (12HL)
- VALVE-OUTFLOW (10HL), ELECTRONIC MODULE 2
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21310076000100
AMM 21-31-00-710-002 Operational Test of the Pressure Control and
Monitoring AMM 21-31-34-000-001 Removal of the Cabin Pressure Controller (11HL,12HL) AMM 21-31-34-400-001 Installation of the Cabin Pressure Controller
(11HL,12HL) AMM 21-31-51-000-002 Removal of the Outflow Valve (10HL) - Electronics Module 10HL-1 (10HL-2) AMM 21-31-51-400-002 Installation of the Outflow Valve (10HL) -Electronics Module 10HL-1 (10HL-2) ASM 21-31/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the pressure control and monitoring system (Ref. AMM TASK 21-31-00-710-002).
4. Fault Isolation
_______________
A. If one or both of the reports, LAST LEG REPORT, PREVIOUS LEG REPORT, and/or the test gives the maintenance message,
- PRESS CONTROLLER 2 (51):
- swap the CPC 2 (12HL) and the CPC 1 (11HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(1) If the fault moves with the CPC 2:
(a) Swap back the CPC 2 (12HL) and the CPC 1 (11HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001).
(b) Replace the CONTROLLER-CABIN PRESSURE 2 (12HL) (Ref. AMM TASK 21-31-34-000-001) and (Ref. AMM TASK 21-31-34-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调1(116)